[AMMRL] PTS Adaptor Card for VNMRS console #agilent #Hardware #Troubleshooting #varian #VarianAgilent

From: brcherry via groups.io <brcherry=asu.edu_at_groups.io>
Date: Wed, 26 Feb 2025 11:19:10 -0800

Hi,

I'm still trying to keep our Varian VNMRS 800 MHz system up and running. 
We've had issues with our frequency synthesizers that have knocked out 2 of our
4 channels.  All four channels in a VFS unit have failed.  I have a
pile of PTS units that still function.  However, my two spare interface
cards seem to have failed.  (0191411603). These are the cards that convert
the VNMRS "ethernet" to the PTS multi pin interface port. 
Without them i can't leverage the PTS frequency Synthesizer to regain 3 or 4
channel function.

Does anyone have any that they are willing to part with?

Thank you,
Brian Cherry
Arizona State University
Magnetic Resonance Research Center


-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#2066): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/2066__;!!PvDODwlR4mBZyAb0!QaaUDe375oQtzok5IMpU0MjV0wgS7C=
UWQCc1gkX4h1H4_ZP2x5UDhuS9BQijdiR8PjbYirEUW1YCIJIEExQtQofn0OQJ$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/111402897=
/7559972__;!!PvDODwlR4mBZyAb0!QaaUDe375oQtzok5IMpU0MjV0wgS7CUWQCc1gkX4h1H4_=
ZP2x5UDhuS9BQijdiR8PjbYirEUW1YCIJIEExQtQsMVWUhX$
Mute #agilent:https://urldefense.com/v3/__https://ammrl.groups.io/g/main/mu=
tehashtag/agilent__;!!PvDODwlR4mBZyAb0!QaaUDe375oQtzok5IMpU0MjV0wgS7CUWQCc1=
gkX4h1H4_ZP2x5UDhuS9BQijdiR8PjbYirEUW1YCIJIEExQtQmGN29vQ$
Mute #hardware:https://urldefense.com/v3/__https://ammrl.groups.io/g/main/m=
utehashtag/hardware__;!!PvDODwlR4mBZyAb0!QaaUDe375oQtzok5IMpU0MjV0wgS7CUWQC=
c1gkX4h1H4_ZP2x5UDhuS9BQijdiR8PjbYirEUW1YCIJIEExQtQlOOL9S4$
Mute #troubleshooting:https://urldefense.com/v3/__https://ammrl.groups.io/g=
/main/mutehashtag/troubleshooting__;!!PvDODwlR4mBZyAb0!QaaUDe375oQtzok5IMpU=
0MjV0wgS7CUWQCc1gkX4h1H4_ZP2x5UDhuS9BQijdiR8PjbYirEUW1YCIJIEExQtQgP4TZU1$
Mute #varian:https://urldefense.com/v3/__https://ammrl.groups.io/g/main/mut=
ehashtag/varian__;!!PvDODwlR4mBZyAb0!QaaUDe375oQtzok5IMpU0MjV0wgS7CUWQCc1gk=
X4h1H4_ZP2x5UDhuS9BQijdiR8PjbYirEUW1YCIJIEExQtQhkkukyk$
Mute #varianagilent:https://urldefense.com/v3/__https://ammrl.groups.io/g/m=
ain/mutehashtag/varianagilent__;!!PvDODwlR4mBZyAb0!QaaUDe375oQtzok5IMpU0MjV=
0wgS7CUWQCc1gkX4h1H4_ZP2x5UDhuS9BQijdiR8PjbYirEUW1YCIJIEExQtQrVvyy_q$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-






IMG_0974.jpg
(image/jpeg attachment: IMG_0974.jpg)

IMG_0976.jpg
(image/jpeg attachment: IMG_0976.jpg)

Received on Wed Feb 26 2025 - 11:52:28 MST

This archive was generated by hypermail 2.4.0 : Fri Feb 28 2025 - 15:51:13 MST