Re: [AMMRL] #agilent #Hardware #VarianAgilent

From: Spin-Doc <bert.heise_at_spin-doc.net>
Date: Wed, 5 Mar 2025 00:21:30 +0100

Hi Gareth,

unfortunately, the past-Inova schematics (besides that rather basic "Hardware
Training Course" which is openly available) are only available "in there", not
"out there". I know of noone "out there" having access to any schematics. But
then again Bruker does the same since quite a few years now - or does anyone
have e.g. AV3 schematics? SGU1/2/3 anyone? HPPR2?

Hopefully a kind soul chooses to change that status whenever Agilent decides
to drop the NMR ball completely in the end - whenever that may be…
Until that time we have to get by figuring out what's going on. Fixing VFS,
synthesizer boards and RefGen boards/modules a spectrum analyzer can be very
handy (check each amplification stage).

Cheers
Bert

> Am 04.03.2025 um 16:06 schrieb Gareth Morris via groups.io:
>
> It’s a long shot, but we have managed to keep our flaky two-channel
> VFS alive for quite a few years by boosting the level of the output of the
> comb generator (we used a TI TRF37D73 broadband amplifier module module).
>
> It’s frustrating to know that schematics must be out there somewhere!
>
>
> Best wishes
>
> Gareth
>


> From: main_at_ammrl.groups.io on behalf of Lin, Penghui via groups.io
> Date: Tuesday, 4 March 2025 at 14:43
> To: main_at_ammrl.groups.io
> Subject: Re: [AMMRL] #agilent #Hardware #VarianAgilent
>
> Thank you all for the replies,
>0
> I forgot to mention that this is a 4-channel VFS module and both channel 3
> and 4 are also bad. Only channel 2 still works for now. So it seems the other
> three channels share some kind of control or gating system?
>0
> I probably shouldn't use the term "easy fix". What I meant is if there is
> any way we can diagnose the component inside the module to find out which
> one(s) goes wrong and possibly replace it in-house.
>
> Since John mentioned that there is no schematics, guess it is almost impossible.....
>
> Penghui
>


Magnetic resonance equipment, service, training & more
Selling & buying used NMR equipment (all vendors)
Dr. rer. nat. Bert Heise
Owner, Applications Scientist

Spin-Doc Bert Heise
Kiefernweg 13
58239 Schwerte
Germany
Mobile: +49 171 5135315
Email: bert.heise_at_spin-doc.net
Web: http://www.spin-doc.net

Representing:
Stelar Fast Field Cycling NMR Relaxometers (http://www.stelar.it
MestreLab NMR Software (http://www.mestrelab.com
Barthel HF Amplifiers (http://www.barthel-hf.de


-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#2108): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/2108__;!!PvDODwlR4mBZyAb0!TNDuzraqD9Bg6K_JZ_ullI8K96WzMf=
XJNlJXoaczn-ikl1zl0i7X9z37ReLjwtZmZxDYyHRAeLJSuguzzc4fSA$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/111440908=
/7559972__;!!PvDODwlR4mBZyAb0!TNDuzraqD9Bg6K_JZ_ullI8K96WzMfXJNlJXoaczn-ikl=
1zl0i7X9z37ReLjwtZmZxDYyHRAeLJSugtxlXnbtA$
Mute #varianagilent:https://urldefense.com/v3/__https://ammrl.groups.io/g/m=
ain/mutehashtag/varianagilent__;!!PvDODwlR4mBZyAb0!TNDuzraqD9Bg6K_JZ_ullI8K=
96WzMfXJNlJXoaczn-ikl1zl0i7X9z37ReLjwtZmZxDYyHRAeLJSugspyUl4eg$
Mute #agilent:https://urldefense.com/v3/__https://ammrl.groups.io/g/main/mu=
tehashtag/agilent__;!!PvDODwlR4mBZyAb0!TNDuzraqD9Bg6K_JZ_ullI8K96WzMfXJNlJX=
oaczn-ikl1zl0i7X9z37ReLjwtZmZxDYyHRAeLJSugsXfiAeWQ$
Mute #hardware:https://urldefense.com/v3/__https://ammrl.groups.io/g/main/m=
utehashtag/hardware__;!!PvDODwlR4mBZyAb0!TNDuzraqD9Bg6K_JZ_ullI8K96WzMfXJNl=
JXoaczn-ikl1zl0i7X9z37ReLjwtZmZxDYyHRAeLJSugv0D6ESqw$
Group Owner: main+owner_at_ammrl.groups.io



Received on Tue Mar 04 2025 - 16:21:33 MST

This archive was generated by hypermail 2.4.0 : Tue Apr 01 2025 - 14:21:16 MST