Hi Luke,
there may be another possible solution (bit more drastic, but here you go):
In case the installation of the new NMR system isn't too far away anymore
you could also just quench the old magnet yourself - being unshielded it's
rather unlikely that it will find a new home (unless you do have such plans
for it of course). Quenching a magnet - specifically an older one which has
a readily accessible vacuum valve - is shockingly easy…
Best regards
Bert
> Am 21.06.2024 um 19:41 schrieb Fulton, Luke <fko24003_at_uconn.edu>:
>
> Hi all,
>
> Thanks for the feedback! We'll probably use Bob's suggestion to stagger the
> installation while waiting for our new magnet. I was fantasizing of some
> way to avoid reconfiguring the plumbing connections to the storage tanks.
> Alas, can't have that cake and eat it too.
>
> Those compass phone apps work great, much more sensitive than expected. i
> With how quickly the field climbs while approaching the magnet I'm realizing
> we don't anything to do with it while moving tanks. There's limited space
> to maneuver and the tanks will be set against a wall. It's a conceivable a
> person might step between the tank and magnet while positioning, and if the
> field grabbed hold while they were there...shudder.
>
> Kind regards,
> Luke
>
> Luke Fulton, PhD
> CHEM BLDG R003
> NMR Core Facility Director
> Unit 3060
> COR2E & Department of Chemistry â€=
> 55 N Eagleville Road
> University of Connecticut
> Storrs, CT 06279
>
> email: fko24003_at_uconn.edu <mailto:fko24003_at_uconn.edu>
> (alias): luke.fulton_at_uconn.edu <mailto:luke.fulton_at_uconn.edu>
> mobile: (603) 953-5275
> Office: (860) 486-4069
Magnetic resonance equipment, service, training & more
Selling & buying used NMR equipment (all vendors)
Dr. rer. nat. Bert Heise
Owner, Applications Scientist
Spin-Doc Bert Heise
Kiefernweg 13
58239 Schwerte
Germany
Mobile: +49 171 5135315
Email: bert.heise_at_spin-doc.net
Web: http://www.spin-doc.net
Representing:
Stelar Fast Field Cycling NMR Relaxometers (
http://www.stelar.it)
MestreLab NMR Software (
http://www.mestrelab.com)
Barthel HF Amplifiers (
http://www.barthel-hf.de)
-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#1366): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/1366__;!!PvDODwlR4mBZyAb0!Rzn7g4HtW8cCVQDUB5VsTIORYRm_tF=
m1V4D69D14FjRXBhPm-8A3A5G0YRozHk5XMGd1_rJt4e1DnI74qm5PqQ$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/106800203=
/7559972__;!!PvDODwlR4mBZyAb0!Rzn7g4HtW8cCVQDUB5VsTIORYRm_tFm1V4D69D14FjRXB=
hPm-8A3A5G0YRozHk5XMGd1_rJt4e1DnI4cFRg77Q$
Mute #heliumrecovery:
https://urldefense.com/v3/__https://ammrl.groups.io/g/=
main/mutehashtag/heliumrecovery__;!!PvDODwlR4mBZyAb0!Rzn7g4HtW8cCVQDUB5VsTI=
ORYRm_tFm1V4D69D14FjRXBhPm-8A3A5G0YRozHk5XMGd1_rJt4e1DnI73Yipzpg$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-
Received on Fri Jun 21 2024 - 12:25:03 MST