Re: [AMMRL] Practical Classics of NMR Literature?

From: Ana Ferreira via groups.io <asd.ferreira=fct.unl.pt_at_groups.io>
Date: Thu, 24 Jul 2025 15:21:06 +0100

Dear all

Following Bob Berno post, those papers are very usefull, particularly the
supplementary information that as the infirmation divided by deuterated
solvent.

Also there was a more recent paper in OPR& that expanded the list. "NMR
Chemical Shifts of Trace Impurities: Industrially Preferred Solvents Used
in Process and Green Chemistry"
https://pubs.acs.org/doi/10.1021/acs.oprd.5b00417

Best

Ana Sofia D. Ferreira, Ph.D.
Chemistry Department, Faculty of *Sciences* and *Technology,*
Universidade *Nova* de Lisboa
2829-516 Caparica, PORTUGAL
E-mail: asd.ferreira_at_fct.unl.pt

On Thu, 24 Jul 2025, 14:47 Bob Berno via groups.io, wrote:

> Hello David,
>
> I was very excited to hear that the Concepts archive is now open access.
> Years ago I'd scanned the Ancient Art of Shimming article from Alex Bain's
> hard copy of the issue, so I was looking forward to having an official PDF
> copy. But when I clicked the PDF download link you sent, I was informed
> that my institution does not provide access to this content. I think our
> library's access only starts in the mid-1990s.
> 🙁
>
> For the synthetic chemistry groups, I have two related papers that I think
> are worth mentioning:
> "NMR Chemical Shifts of Common Laboratory Solvents as Trace Impurities" J.
> Org. Chem. 1997, 62, 7512-7515 and
> "NMR Chemical Shifts of Trace Impurities: Common Laboratory Solvents,
> Organics, and Gases in Deuterated Solvents Relevant to the Organometallic
> Chemist" Organometallics 2010, 29, 2176–2179
>
> The 1997 JOC paper is an excellent resource for the average organic
> chemist, but the updated version in 2010 has a much more expanded list of
> common reagents and solvents that you will see in the typical NMR spectrum
> from a synthetic chemistry group. I tell students to actually PRINT the
> tables of 1H and 13C chemical shifts and post these tables above their desk
> for quick reference.
>
> Cheers,
> Bob.
>
> On 2025-07-23 2:51 p.m., David Rovnyak via groups.io wrote:
>
> Quick tip: as libraries reduce their physical holdings, ask your library
> for the hard copies of the Concepts issues before they get discarded.
>
> The Concepts archive is largely open access at:
> https://onlinelibrary.wiley.com/loi/6471
>
> Quick link to the Keifer article:
>
> https://onlinelibrary.wiley.com/doi/10.1002/*28SICI*291099-0534*281999*2911*3A3*3C165*3A*3AAID-CMR4*3E3.0.CO*3B2-D
>
> And the ancient art of shimming:
> https://onlinelibrary.wiley.com/doi/10.1002/cmr.1820020303
>
> -David
>
>
> ------------------------------------------------------------------------
> David Rovnyak, Professor of Chemistry, Bucknell Univ., Lewisburg, PA 17837
> BlueSky : NMR_Guy <https://bsky.app/profile/nmrguy.bsky.social>
> Research: http://www.facstaff.bucknell.edu/drovnyak/
> Bucknell Chemistry: http://www.departments.bucknell.edu/chemistry/
>
> Pascal: "I would like to have written a shorter letter, but I didn't have
> the time"
>
> ------------------------------------------------------------------------
>
>
> -- Dr. Bob Berno Manager, NMR Facility McMaster University, ABB-156 1280
> Main St. West Hamilton, ON L8S 4M1
> T: 905-525-9140 x24158 or x24686
> ------------------------------------------------------------------------
> This email contains CONFIDENTIAL information intended for the specific
> recipient(s). If you have an accommodation need for a planned meeting,
> please e-mail me directly and I will do my best to make appropriate
> arrangements. Should you require any materials sent via this e-mail address
> in an alternate/accessible format, please let me know. McMaster University
> sits on the traditional Territories of the Mississauga and Haudenosaunee
> Nations, and within the lands protected by the "Dish With One Spoon" wampum
> agreement.
>


-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#2544): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/2544__;!!PvDODwlR4mBZyAb0!WJasryr7xpvfdSgkaWAapmtq7VAPSk=
bwgKC-ow74WunQPwU8w71qyULd0BoQMRXd7PPesJiE1czLA99rQfszXyRl7Zcm$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/114305320=
/7559972__;!!PvDODwlR4mBZyAb0!WJasryr7xpvfdSgkaWAapmtq7VAPSkbwgKC-ow74WunQP=
wU8w71qyULd0BoQMRXd7PPesJiE1czLA99rQfszX__IcXdz$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-




Received on Thu Jul 24 2025 - 07:48:01 MST

This archive was generated by hypermail 2.4.0 : Sat Aug 02 2025 - 14:13:11 MST