Good morning
I have a *TopSpin-3.7* / *Alma-9* / *Avance-III* system used mostly for
automation with ICON (BACS). The system is stable but occasionally the
workstation becomes slow when the second, external, non-spectrometer
network goes down. I have no grumbles about performance or stability (HP
Z4-G4 workstation from Bruker).
A desktop icon has never been necessary. The *XFCE* menu contains a Bruker
software category and the system is largely used for ICON automation so
routine users have no need of a desktop icon. It should be possible to add
desktop icons if required.
*XFCE* is the default desktop (no problems with this).
I have no experience with IBS.
Kind regards,
Craig.
On Thu, 22 Jan 2026 at 00:16, Gerd Gemmecker via groups.io <Gerd.Gemmeckertum.de_at_groups.io> wrote:
> Walter Zhang via groups.io schrieb:
>
>
>
> We are planning to upgrade the computer for an AV III HD system, and I
> would like to ask for your experience with running *TopSpin 3.6 on
> AlmaLinux 9*.
>
> In particular, I would greatly appreciate your feedback on the following
> questions:
>
>
>
> 1. *TopSpin 3.6 on AlmaLinux 9*
> What has been your experience running TopSpin 3.6 on AlmaLinux 9?
> Have you encountered any issues related to stability, performance, or
> software compatibility?
>
>
> so far we have migrated a few of our AV III / III HD spectrometers from
> Centos to Alma9. Initially we were running Topspin3.5pl7, but have then
> upgraded to 3.7.0
> and now to 3.8.0 without any problems. We more or less skipped 3.6,
> because we had sticked to 3.5pl7 for longer (on Centos) and then directly
> went to the newer ones.
> They (both 3.7 and 3.8) seem pretty stable.
>
>
> 1. *Desktop icons in AlmaLinux 9*
> The default Desktop environment (Standard, X11 display server) in
> AlmaLinux 9 as configured by Bruker does not display desktop icons.
> Has anyone successfully used *XFCE* or *KDE* as the desktop
> environment for operating the NMR spectrometer?
>
>
> we are using Gnome as a standard, and we have icons for e.g. certain
> directories on the desktop.
> Not for Topspin itself, since it is available from the applications menu
>
>
> 1. *IBS compatibility with TopSpin 3.7*
> I previously attempted to use IBS with TopSpin 3.7 but was unable to
> get it working.
> Has anyone successfully configured IBS with TopSpin 3.7, and if so,
> are there any special configuration steps or recommendations?
>
> no experience with "IBS" (and not sure what it means)
>
> Ciao,
>
> Gerd
>
> -- PD Dr. Gerd Gemmecker Bayerisches NMR-Zentrum NAT School, TU München
> Lichtenbergstr. 4 D-85747 Garching Germany Raum/Room 2108 / BNMRZ,
> E.O.Fischer-Str. 2 Tel. +49 (89) 289-52604 Fax +49 (89) 289-52669 e-mail:
> Gerd.Gemmecker_at_ch.tum.de Internet: http://www.gemmecker.de
>
>
>
-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#3145): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/3145__;!!PvDODwlR4mBZyAb0!X8uaySwXqsiuyfMmJTvU9VAKgJEPEn=
ZIndZw6iW1wYEy8SM7ld-m989ENjrTnfXYztTL6JHkFv0TWV5mfhPi7d0glLj2$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/117388545=
/7559972__;!!PvDODwlR4mBZyAb0!X8uaySwXqsiuyfMmJTvU9VAKgJEPEnZIndZw6iW1wYEy8=
SM7ld-m989ENjrTnfXYztTL6JHkFv0TWV5mfhPi7ZNfkbJp$
Group Owner: main+owner_at_ammrl.groups.io
Unsubscribe: https://urldefense.com/v3/__https://ammrl.groups.io/g/main/lea=
ve/12177410/7559972/1125599165/xyzzy__;!!PvDODwlR4mBZyAb0!X8uaySwXqsiuyfMmJ=
Received on Sat Jan 24 2026 - 05:58:45 MST