[Fwd: PC Processing etc]

Gary Juneau (nmr@decaturcenter.com)
Wed, 18 Jul 2001 11:03:24 -0500


This is a multi-part message in MIME format.
--------------D14B34E178462B0BFB900C29
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit



--------------D14B34E178462B0BFB900C29
Content-Type: message/rfc822
Content-Transfer-Encoding: 7bit
Content-Disposition: inline

X-Mozilla-Status2: 00000000
Message-ID: <3B55B320.A7844724@decaturcenter.com>
Date: Wed, 18 Jul 2001 11:02:40 -0500
From: Gary Juneau 
Reply-To: nmr@decaturcenter.com
Organization: NMR Analysis and Consulting
X-Mailer: Mozilla 4.7 [en]C-CCK-MCD EBM-Compaq  (Win95; U)
X-Accept-Language: en
MIME-Version: 1.0
To: Lazaros Kakalis 
Subject: Re: PC Processing etc
References: <004101c10f02$d1350a70$13200680@rutgers.edu>
Content-Type: multipart/alternative;
 boundary="------------09E8964819D9A0B3518DDDBD"


--------------09E8964819D9A0B3518DDDBD
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit

Dear Lazaros,

I'm trying to do this myself.  I have an old Varian VXR, and Nuts
software on the PC.  At present I have to copy spectral data to a 5 1/4"
floppy (remember those!), change the format to something Nuts can use
with V Helper from Steve Silber of Texas A&M, and then use Nuts on a
different PC to look at the data.

I'm trying to get around this headache by connecting  the VXR to a PC
via  RS232 ports.  I have the Varian software for the VXR but I'm still
having trouble on the PC end.  MS Hyperterminal didn't seem to work.  I
downloaded a copy of Unix for Windows and I'm looking at this avenue.

I'd appreciate any experience or advice you or anyone else has in this
area.

Gary Juneau,   NMR Analysis and Consulting.

Lazaros Kakalis wrote:

> Dear AMMRLers, We would like to process off-line Varian 1D and 2D fids
> using PCs and low-cost software / freeware.We would also like to
> import processed spectra in WORD documents. Can you please share your
> experiences and thoughts? Thanks!  Lazaros Kakalis Rutgers University
> at Newark
> Department of Chemistry
> 73 Warren Street
> Newark, NJ 07102-1811
>
> Tel: (973) 353-5040 (office, lab)
> Tel: (973) 353-5329 (secretary)
> Fax: (973) 353-1264
> Email: kakalis@andromeda.rutgers.edu

--------------09E8964819D9A0B3518DDDBD
Content-Type: text/html; charset=us-ascii
Content-Transfer-Encoding: 7bit




Dear Lazaros,

I'm trying to do this myself.  I have an old Varian VXR, and Nuts software on the PC.  At present I have to copy spectral data to a 5 1/4" floppy (remember those!), change the format to something Nuts can use with V Helper from Steve Silber of Texas A&M, and then use Nuts on a different PC to look at the data.

I'm trying to get around this headache by connecting  the VXR to a PC via  RS232 ports.  I have the Varian software for the VXR but I'm still having trouble on the PC end.  MS Hyperterminal didn't seem to work.  I  downloaded a copy of Unix for Windows and I'm looking at this avenue.

I'd appreciate any experience or advice you or anyone else has in this area.

Gary Juneau,   NMR Analysis and Consulting.

Lazaros Kakalis wrote:

Dear AMMRLers, We would like to process off-line Varian 1D and 2D fids using PCs and low-cost software / freeware.We would also like to import processed spectra in WORD documents. Can you please share your experiences and thoughts? Thanks!  Lazaros Kakalis Rutgers University at Newark
Department of Chemistry
73 Warren Street
Newark, NJ 07102-1811

Tel: (973) 353-5040 (office, lab)
Tel: (973) 353-5329 (secretary)
Fax: (973) 353-1264
Email: kakalis@andromeda.rutgers.edu  

--------------09E8964819D9A0B3518DDDBD-- --------------D14B34E178462B0BFB900C29--