If you would like to consider an alternative, you could try what we do. We
have one OVJ user called walkup, who has a list of operators. The creation
of operators is a simple process of editing six text files split between /vnmr
and /home/walkup/vnmrsys/persistence.
Operators have a very light footprint, although they don't get the benefit
of their own macro library.
Regards,
Scott
Scott K. Smith, Director of NMR Spectroscopy
The University of Texas at Austin | Chemistry | 832-294-1928 | utexas.edu
NMRlab homepage: IoNMR | Nuclear Magnetic Resonance Labs (utexas.edu) https://ionmr.cm.utexas.edu/
________________________________
> From: main_at_ammrl.groups.io on behalf of Shawn Wagner
> Sent: Tuesday, September 10, 2024 1:50 PM
> To: main_at_ammrl.groups.io <main_at_ammrl.groups.io>
> Subject: Re: [AMMRL] VnmrJ Admin Program
Thanks for the input coming in.
Hi Eugenio,
This is exactly what we are looking to do. We want to be able to create the
user login account in Ubuntu22 and then set up the user with an OpenVnmrJ
operational account that contains the most current system setup for 5 different
systems remotely. I have analyzed how OpenVnmrJ Admin sets everything up but
have not started to replicate it. We have computer people and students that
are going to make a tailored system for our NMR and about 15 other instruments
so we can use this one program to set up new users on equipment they need to use.
If you could share scripts that you have created that would be a great help
to see how your have done it to make sure we are not missing anything.
Shawn
________________________________
> From: main_at_ammrl.groups.io on behalf of Eugenio Alvarado
> Sent: Tuesday, September 10, 2024 6:43 AM
> To: main_at_ammrl.groups.io <main_at_ammrl.groups.io>
> Subject: Re: [AMMRL] VnmrJ Admin Program
Shawn,
We use a couple of bash scripts to create identical user accounts in all our
computers in the lab. The first one is used to connect via ssh to all computers
in the lab to run the second script which creates a user using the parameters
passed along. We set up passwordless ssh so we only need to enter the password
once. These scripts are heavily tailored to our needs (not only they create a
linux and vnmr account but also the vnmr and desktop environments) but you could
use them as a model or modify them to make your own. I can send them to you
if you want them.
Eugenio
Eugenio Alvarado, Ph.D.
NMR Facility Director Chemistry Department,
room 3500.
University of Michigan
930 N. University Ave.,
Ann Arbor, MI 48109-1055.
Voice: (734)-764-9924
On 9/9/24 14:47, Shawn Wagner wrote:
Has any attempted to replicate what the VnmrJ Admin program does?
We have 5 different NMR computers and would like to be able to add the same
user to each instrument computer without have to do it individually, so a
script that can ssh into each computer and perform the necessary file
manipulations and permission changes would be quite useful.
Don't want to reinvent the wheel if someone has done this.
Thanks,
Shawn
Shawn Wagner, PhD
Director of Chemistry Instrumentation Resources
Laird J. Stabler Memorial Hall
LJS 160
840 Downey Way
Los Angeles, CA 90089
-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#1622): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/1622__;!!PvDODwlR4mBZyAb0!SDqKWoRyNcAFUhb52fMQ7cnL_IFFwy=
t2KTDnsXN3WLgH6duNa8qRPXN3KKGVQjIczX7weEbGovjmmln1Frng15bmaM5N$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/108360909=
/7559972__;!!PvDODwlR4mBZyAb0!SDqKWoRyNcAFUhb52fMQ7cnL_IFFwyt2KTDnsXN3WLgH6=
duNa8qRPXN3KKGVQjIczX7weEbGovjmmln1Frng1-qEWW0m$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-
Received on Thu Sep 19 2024 - 09:37:37 MST