FW: AMMRL: Bruker folders

From: Patrick Wheeler <patrick.wheeler_at_acdlabs.com>
Date: Tue, 27 Oct 2015 20:57:25 +0000

Hello AMMRL Folks,

I’m very sensitive to the culture of AMMRL (having been a member for ~20 years?) and so am offering this quick note as a matter of information for the membership rather than as a commercial offering.

ACD/Spectrus Processor automatically recognizes data by experiment type for most common experiments, and allows the user to browse the data – labeling it automatically. The data does not have to be loaded first. Data that is loaded for viewing is also labeled by watermark in the spectrum processing fields. Unknown data types can be mapped by the user to extend the capabilities of the software.

Best regards,

Patrick Wheeler
ACD/Labs
NMR Product Manager
+1-858-395-2023

From: Plant,Daniel [mailto:dan_at_mbi.ufl.edu]
Sent: Monday, October 26, 2015 12:17 PM
To: 'Kenneth Knott' <kknott_at_vt.edu>; ammrl_at_ammrl.org
Cc: Plant,Daniel <dan_at_mbi.ufl.edu>
Subject: RE: AMMRL: Bruker folders

Hi Ken,
Wouldn’t the suggestion from Clemens satisfy your need to label the dataset. Ie Sample1-1D-TOCSY.
The beauty of the numbering system is that you may then collect several exps under the same name.
Ie. Exps 1, 2, 3 might be 3 different mixing times.

My experience has been that the Hotline has always been helpful.
Best regards,
Dan


From: Kenneth Knott [mailto:kknott_at_vt.edu]
Sent: Monday, October 26, 2015 9:50 AM
To: ammrl_at_ammrl.org<mailto:ammrl_at_ammrl.org>
Subject: Re: AMMRL: Bruker folders

Thanks everyone for the suggestions and input.. But I think I've found a correlation. The people who aren't too bothered by the Bruker data system are those using Topspin and it's included browser to process their data.

Unfortunately, many of us process our data off the instrument using alternative means. We, here at Virginia Tech, use Mnova to process our data for a number of reason. The first being we find it to be superior to all others in processing. But also for a number of other reasons.

1) Users our trained on one processing software package in a multiplatform environment (Mix of Burker and Agilent/Varian sytems)
2) NUS processing is included (for free) and far superior (much faster) to Topsim

In any case, when processing outside of Topshim you rely on the file. system to describe your data sets. Here is where Topshim fails miserably...

1) Exp numbers for folders is wholly undescriptive...
2) Even inside the folder, one cannot tell at a glance what the experiment is outside of 1D or 2D

Sure there are ways around this once the data is loaded into Mnova using titles, but Bruker Topspin falls far short in this regard and I'm astonished that you cannot give the experiment folders any kind of descriptor.

Thanks again for the help.



On Fri, Oct 23, 2015 at 3:38 PM, Kenneth Knott <kknott_at_vt.edu<mailto:kknott_at_vt.edu>> wrote:
So one thing that has always frustrated me about Topspin is that is saves all folders simply by the experimetn number. This gets very difficult to keep track of when I've got a suite of experiments or add to them over time.

It seems to me that there must be a way to alter this to save perhaps by experiment number AND parameter set.. for example 10-C13CPD or 20-PROTONRO, etc...

Can this be done? If not, how do you get around this issue?

I have found the bruker 'hotline' to be less than helpful with issues such as this...

Thanks!

--
Ken Knott
Department of Chemistry
Analytical Services
Virginia Tech

(540)267-6502<tel:%28540%29267-6502> (Cell)
(540)231-0885<tel:%28540%29231-0885> (Office)



--
Ken Knott
Department of Chemistry
Analytical Services
Virginia Tech

(540)267-6502 (Cell)
(540)231-0885 (Office)
Received on Tue Oct 27 2015 - 10:57:25 MST

This archive was generated by hypermail 2.4.0 : Mon Jun 19 2023 - 16:42:50 MST