[AMMRL] Topspin VT Display issues #Bruker #NMR_Aquisition_Software #NMR_Liquids #Troubleshooting

From: gpwylie via groups.io <gpwylie=tamu.edu_at_groups.io>
Date: Fri, 07 Aug 2026 07:13:55 -0700

Hi Everyone

We are running Topspin 4.5.0 on a 500 NEO with Alma Linux. When doing VT work
the software will randomly lock up and you have to kill it and reopen it. Or
more common the pop-ups for target temp or gas flow will lock up and you can
not type in them. They can be closed and reopened but you can still not type
in them. When this happens you can still type in the main Topspin window and
most everything seems normal. So far the only fix we have found for this is
to again close Topspin and reopen it.

Is anyone else having similar issues or found a solution? This has been happening
for awhile now.

Thanks
Greg

Gregory P. Wylie, Ph.D
NMR Facility Manager
Texas A&M University
Department of Chemistry #3255
580 Ross St.
College Station, TX  77843-3255
gpwylie_at_tamu.edu
979.458.0705 (voice)
979.845.4719 (fax)
http://nmr.tamu.edu


-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#3672): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/3672__;!!PvDODwlR4mBZyAb0!SuER-TY6zAaD4GRLWQ5MFb5rHeBuZO=
yd11NNolNPhMTKW9BlRc9R61QQmKosO2Y_iII7aqIJCFFxw3ivy7OA41UhkVZM$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/120643015=
/7559972__;!!PvDODwlR4mBZyAb0!SuER-TY6zAaD4GRLWQ5MFb5rHeBuZOyd11NNolNPhMTKW=
9BlRc9R61QQmKosO2Y_iII7aqIJCFFxw3ivy7OA4_zgWDAz$
Mute #nmr_aquisition_software:https://urldefense.com/v3/__https://ammrl.gro=
ups.io/g/main/mutehashtag/nmr_aquisition_software__;!!PvDODwlR4mBZyAb0!SuER=
-TY6zAaD4GRLWQ5MFb5rHeBuZOyd11NNolNPhMTKW9BlRc9R61QQmKosO2Y_iII7aqIJCFFxw3i=
vy7OA4_5P6a4k$
Mute #nmr_liquids:https://urldefense.com/v3/__https://ammrl.groups.io/g/mai=
n/mutehashtag/nmr_liquids__;!!PvDODwlR4mBZyAb0!SuER-TY6zAaD4GRLWQ5MFb5rHeBu=
ZOyd11NNolNPhMTKW9BlRc9R61QQmKosO2Y_iII7aqIJCFFxw3ivy7OA49L6ewPV$
Mute #troubleshooting:https://urldefense.com/v3/__https://ammrl.groups.io/g=
/main/mutehashtag/troubleshooting__;!!PvDODwlR4mBZyAb0!SuER-TY6zAaD4GRLWQ5M=
Fb5rHeBuZOyd11NNolNPhMTKW9BlRc9R61QQmKosO2Y_iII7aqIJCFFxw3ivy7OA42liy_Cs$
Mute #bruker:https://urldefense.com/v3/__https://ammrl.groups.io/g/main/mut=
ehashtag/bruker__;!!PvDODwlR4mBZyAb0!SuER-TY6zAaD4GRLWQ5MFb5rHeBuZOyd11NNol=
NPhMTKW9BlRc9R61QQmKosO2Y_iII7aqIJCFFxw3ivy7OA4wexXsG4$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-




Received on Fri Aug 07 2026 - 07:20:38 MST

This archive was generated by hypermail 2.4.0 : Tue Sep 01 2026 - 13:53:27 MST