Please do not reply to this message via “Reply” or â€=
œReply All”.
Instead, send all responses directly to Pedro at: pedro_at_psu.edu<mailto:pedr=
o_at_psu.edu>.
This message is being posted to the AMMRL NMR manager list on behalf of Ped=
ro R. Trinidad‑Pérez, a Chemistry graduate student at Penn Sta=
te University.
Hello AMMRL,
Hope you are all good!
My name is Pedro R. Trinidad-Pérez, a Chemistry graduate student at Penn
State University.
Recently, I created a safety initiative in my department where I made an NMR
holder design (attached are some pictures) and collaborated with our university
MakerSpace to 3D print 100+ holders and distribute them to all users/students
who use our NMR facilities on campus to improve the problem of transporting NMR
samples with a proper secondary containment. This initiative was very well
received, with strong support and enthusiasm from the NMR facility, users, faculty,
and our safety and EHS staff. This motivated me to start reaching out to other
Universities with NMR facilities to freely share this initiative and the design
files so they can offer this holder to their students/users. Currently, I have
reached out to 60+ universities and NMR facilities in the US, with many showing
interest in this initiative, and some have already adopted it, with users using my
design and providing positive feedback!
I was recommended by one of the NMR directors to contact AMMRL about the possibility
of helping disseminate this safety initiative and NMR holder designs to AMMRL members.
Please feel free to contact me with any specific questions, feedback or suggestions
to improve the models!
Attached are the files/models of the holder and its cap.
I have been printing them on Prusa MK4S printers (any other printers that
accommodate the size of the holder body will work), and I am using these general
settings to get the best quality for the numbers on the top and for body/cap
fitment, though they might be slightly different on other printers.
Layer height 0.2 mm
Perimeter/walls 3
Infill density 3% with Gyroid pattern
No support or brim
I have also posted the models publicly in these websites where they can also
download them for free:
https://www.thingiverse.com/thing:7371254
https://cults3d.com/en/3d-model/various/nmr-tube-holder
https://www.printables.com/model/1757297-nmr-tube-holder
https://makerworld.com/en/models/2946397-nmr-tube-holder?from=search
Cordially,
Pedro R. Trinidad-Pérez (he/him/his)
PhD Candidate - Hodges Research Group <
https://www.hodgeschemistry.com/ >
Department of Chemistry
The Pennsylvania State University
NSF Graduate Research Fellow
-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#3674): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/3674__;!!PvDODwlR4mBZyAb0!Q9JGc9Sr30UXoTvMG5PiWcMhBRPsjH=
O7BEVRhsoY_nq9wrVZCxhFem0uV05M0hyivRJBAABwp4GYcs6-Ap86IVQc$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/120647325=
/7559972__;!!PvDODwlR4mBZyAb0!Q9JGc9Sr30UXoTvMG5PiWcMhBRPsjHO7BEVRhsoY_nq9w=
rVZCxhFem0uV05M0hyivRJBAABwp4GYcs6-AtP6L1yU$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-
Received on Fri Aug 07 2026 - 11:36:51 MST