Hi Heike,

I would like to second Josh Kurutz's policy statement. It is pretty
thorough. The lab at Boise State operates in a very similar way with a few
exceptions.

-We do not have a policy about wearing lab coats in the lab but it does
make sense to prohibit them since I am sure that many have contamination,
particularly on their sleeves.
-We do not allow users to wear gloves from outside of the NMR lab. We do
supply gloves within the NMR lab if a student prefers to use them, but I
make it clear to the students that the outside of the tubes should be
clean, free of dust, finger oil, and other chemicals.
-We require that the student use a tube carrier to transport the NMR
samples from their lab to the NMR facility. We have cheap clear plastic
tubes (and caps) in 4 foot lengths which we cut into 10 inch pieces for
them to use. The plastic degrades in the synthetic lab over time so I keep
an eye on them and tell them to ask for a new one when the old one gets
crazed or brittle.
-We do not have any prep space so on a very limited basis we have allowed
the use of reaction initiators in the NMR lab on a case by case basis but
they must bring in a limited quantity of initiator in a seal bottle with a
septum cap and inject the initiator into the screw top tube with a septum
cap and work within a small bin that they bring with them to the lab.
- no safety glasses are required unless they are doing significant
Variable Temperature work.

On a side issue we have sample changers and therefore have extra spinners
(I refer to them as shuttles with the students since we never spin) and I
teach users to never touch the shuttles (as per Bruker's recommendation) so
the gloves provided in the lab are handy for that purpose too.

Regards,

Joe
*******************************
Joe Dumais, Ph.D. (retired)
Associate Research Professor/Nuclear Magnetic Resonance Spectroscopist
Boise State University
College of Arts and Sciences
Department of Chemistry and Biochemistry
1910 University Drive, Boise, Idaho 83725-1520
(208) 426 4913
http://chemistry.boisestate.edu/
*******************************

Sent from my MS Windows PC


-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#1474): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/1474__;!!PvDODwlR4mBZyAb0!XOXtSml2v9fZI-nWt8wXh9Ho0zttS_=
a1_rTLu1pmAgNFqgHGOPlVrbXVaaGjqTsTtZojUYfkSsY-MAB0RJfrf6QmFcw$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/107749189=
/7559972__;!!PvDODwlR4mBZyAb0!XOXtSml2v9fZI-nWt8wXh9Ho0zttS_a1_rTLu1pmAgNFq=
gHGOPlVrbXVaaGjqTsTtZojUYfkSsY-MAB0RJfrqGtXbhI$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-




Received on Tue Aug 06 2024 - 10:18:02 MST

This archive was generated by hypermail 2.4.0 : Sun Sep 01 2024 - 15:22:33 MST