I¡¯ve been volunteered to find a new home for a complete mouse imaging system we have here, although if anyone is interested in the magnet only that¡¯s a possibility. We¡¯re not trying to make any money, but whoever wants the system would be responsible for relocation costs. The system collected useful data within the last 2 weeks.
If you might be interested, or if you¡¯re not interested but know somebody who might be, please contact me directly. I¡¯ll include the system specs below along with my contact info at the end.
Cheers,
Andrew
4.7T mouse imaging system at University of Iowa
Magnet: Magnex MRBR 4.7T 160 mm bore, actively shielded, installed ~July 2004
SN hand scratched on plate, poorly legible, looks like 04*50
SN on gradients is 31314, also hand scratched
Magnex E5031 N2 level monitor - working
Magnex E7007 Emergency discharge - never used, probably working
Magnex E5011 He level monitor - not working
helium fill every ~5 months takes ¡Â250 L He transfer tube for fills is available
Console: Varian Inova imaging console, SN 011937, PPC CPU board
data board has 16 MB memory
XYZ gradient boards and (external) amplifiers with chiller
270 mT/m, 0.1 ms rise, 5% duty cycle at full power
high order shims not working (usually not used for imaging), suspected flash memory problem
current workstation is Sun Blade 2000, VnmrJ 1.1D
console can run from Linux box and VnmrJ 4.2
Probes: 4 probes/coils are available
Original Varian probe, widest coil, worked when last used 3 Doty probes, all working:
mouse head coil, 25 mm diameter x ~25 mm long mouse torso coil, 38 mm diameter x ~40 mm long mouse full body coil, 38 mm diameter and longer
Many of the original manuals are available as well.
--
C. Andrew Fowler, Ph.D. | University of Iowa
Associate Director | B291 CBRB, 500 Newton Rd.
CCOM NMR Facility | Iowa City, IA 52242
319-384-2937 (office) | 319-335-7273 (fax)
andrew-fowler_at_uiowa.edu
________________________________
Notice: This UI Health Care e-mail (including attachments) is covered by the Electronic Communications Privacy Act, 18 U.S.C. 2510-2521 and is intended only for the use of the individual or entity to which it is addressed, and may contain information that is privileged, confidential, and exempt from disclosure under applicable law. If you are not the intended recipient, any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this communication in error, please notify the sender immediately and delete or destroy all copies of the original message and attachments thereto. Email sent to or from UI Health Care may be retained as required by law or regulation. Thank you.