The part you need to get is Z118434 GASANSCHLUSS – ADAPTER J
Regards
Clemens
==========================
==========================
========
Clemens Anklin Ph.D. Vice President
Bruker BioSpin NMR Applications & Training
15 Fortune Drive Phone: 978 313 5NMR (5667)
Billerica MA 01821 Bluesky _at_canklin.bsky.social
web: http://www.bruker.com
e-mail: clemens.anklin_at_bruker.com
==========================
==========================
========
Now is the best time to learn something new!
https://www.bruker.com/en/landingpages/bbio/world-class-bruker-nmr-trainings.html
==========================
==========================
========
-Bruker Confidential-
> From: main_at_ammrl.groups.io On Behalf Of Juergen Schulte via groups.io
> Sent: Friday, April 17, 2026 11:07 AM
> To: main_at_ammrl.groups.io
> Subject: Re: [External Email] [AMMRL] BCU-05 with modern probes
Like this?
It was included either in our 600 MHz BBFO probe or our BCU-I.
Best Regards,
Jürgen
_______________________________________________
Jürgen Schulte, Ph. D.
NMR Specialist
Binghamton University
SN Building, RM 1024
25 Murray Hill Road
Vestal, NY 13850
Ph.: 607-777-4405 Fax: 607-777-4478
schulte_at_binghamton.edu
http://chemiris.binghamton.edu/NMR/Schulte
> From: main_at_ammrl.groups.io On Behalf Of Samuel Digby via groups.io
> Sent: Thursday, April 16, 2026 5:49 AM
> To: main_at_ammrl.groups.io<mailto:main_at_ammrl.groups.io>
> Subject: [External Email] [AMMRL] BCU-05 with modern probes
Hi all,
I was wondering if anyone here has experience with connecting old BCU-05 hosing
(with the female ball joint end) to modern probes (e.g. iProbes with the screw-on
Johnston coupling, not the male ball-joint). I've got adaptors for connecting these
probes directly to the BSVT gas output (bypass the chiller altogether), and for
connecting a modern BCU-I/II to an older ball-jointed probe (which isn't much
use for me).
Any insight would be much appreciated as to whether the appropriate adaptors
for this desired configuration exist, or if anyone has Macgyvered this without
having to upgrade to a new BCU. I've seen Bruker engineers screw the hosing
straight onto the probe without any straight insert Johnston coupler in a
previous job (but it's very inelegant and not a long term solution - it's
barely attached).
Regards from the UK,
Sam
Samuel Digby MChem Oxon
Technical Manager (NMR)
Department of Chemistry
Faculty of Natural, Mathematical & Engineering Sciences
King's College London
Britannia House| 7 Trinity Street | Guy’s Campus | London | SE1 1DB
samuel.digby_at_kcl.ac.uk |
http://www.kcl.ac.uk/chemistry
-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#3392): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/3392__;!!PvDODwlR4mBZyAb0!SbgJIQk9uRLD6N9QnwOQeV4RQ_Nf9P=
il3e16gpc1DaT94RXcbJrCFa9j0tWz1JyXZNaq32y-CQfQ5REpGZBWkKbMHPFn$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/118877087=
/7559972__;!!PvDODwlR4mBZyAb0!SbgJIQk9uRLD6N9QnwOQeV4RQ_Nf9Pil3e16gpc1DaT94=
RXcbJrCFa9j0tWz1JyXZNaq32y-CQfQ5REpGZBWkNwQN2ao$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-
Received on Fri Apr 17 2026 - 09:39:19 MST