Email Archives for November, 2023 by thread
50 messages
:
Starting
Wed Nov 01 2023 - 07:04:55 MST,
Ending
Thu Nov 30 2023 - 11:33:25 MST
This period
:
Most recent messages
sort by
: [ thread ] [
author
] [
date
] [
subject
] [
attachment
]
Nearby
: [
Other mail archives
]
Re: [AMMRL] Bruker Topspin 4.2 vs 4.3
Yongbo Zhang
(Wed Nov 01 2023 - 06:59:06 MST)
Re: [AMMRL] Bruker Topspin 4.2 vs 4.3
Beth M
(Wed Nov 01 2023 - 07:54:06 MST)
Re: [AMMRL] Bruker Topspin 4.2 vs 4.3
JOHN RALPH via groups.io
(Wed Nov 01 2023 - 10:21:01 MST)
Re: [AMMRL] Bruker Topspin 4.2 vs 4.3
Scott Burt
(Thu Nov 09 2023 - 09:00:48 MST)
Re: [External Email] Re: [AMMRL] Bruker Topspin 4.2 vs 4.3
Mike.Lumsden_at_dal.ca
(Wed Nov 01 2023 - 07:40:44 MST)
[AMMRL] OneNMR probe
Shawn Wagner
(Wed Nov 01 2023 - 12:38:18 MST)
Re: [AMMRL] OneNMR probe
Darcy Burns
(Wed Nov 01 2023 - 14:05:55 MST)
Re: [AMMRL] OneNMR probe
Shawn Wagner
(Wed Nov 01 2023 - 14:45:04 MST)
Re: [AMMRL] ALMA 9: progress and issues?? #Troubleshooting #varian #agilent #Bruker #NMR_Aquisition_Software
gregory.wylie_at_chem.tamu.edu
(Thu Nov 02 2023 - 07:06:40 MST)
[AMMRL] LN2 sensor error in TopSpin
Roberts, Jessica
(Fri Nov 03 2023 - 12:29:37 MST)
Re: [AMMRL] LN2 sensor error in TopSpin
clarkson.michael via groups.io
(Mon Nov 06 2023 - 10:06:24 MST)
[AMMRL] Helium recovery during refill
Alvaro Herrera
(Mon Nov 06 2023 - 10:22:52 MST)
Re: [AMMRL] Helium recovery during refill
gregory.wylie_at_chem.tamu.edu
(Mon Nov 06 2023 - 12:18:24 MST)
Re: [AMMRL] Helium recovery during refill
Baber, James (NIH/NIDDK) [E] via groups.io
(Mon Nov 06 2023 - 12:43:01 MST)
Re: [AMMRL] Helium recovery during refill
Jeff Walton via groups.io
(Thu Nov 09 2023 - 16:54:02 MST)
Re: [AMMRL] Helium recovery during refill
Xia, Youlin via groups.io
(Fri Nov 10 2023 - 08:15:07 MST)
[AMMRL] Measuring instrument use/capacity
Kenneth Sharp-Knott
(Tue Nov 07 2023 - 10:52:02 MST)
Re: [AMMRL] Measuring instrument use/capacity
Sukenick, George
(Tue Nov 07 2023 - 13:45:38 MST)
Re: [AMMRL] Measuring instrument use/capacity
Walt Massefski
(Tue Nov 07 2023 - 14:08:11 MST)
Re: [AMMRL] Measuring instrument use/capacity
gregory.wylie_at_chem.tamu.edu
(Tue Nov 07 2023 - 15:29:29 MST)
Re: [AMMRL] Measuring instrument use/capacity
CHARLES G FRY via groups.io
(Tue Nov 07 2023 - 14:14:19 MST)
Re: [AMMRL] Measuring instrument use/capacity
Ian Luck via groups.io
(Tue Nov 07 2023 - 15:00:59 MST)
[AMMRL] two 800 MHz solid-state MAS probes available / Texas A&M #Bruker #Hardware #NMR_Solids
gregory.wylie_at_chem.tamu.edu
(Wed Nov 08 2023 - 14:32:16 MST)
[AMMRL] Contour levels in Topspin
John H Grimes Jr.
(Fri Nov 10 2023 - 14:05:27 MST)
Re: [AMMRL] Contour levels in Topspin
prashansa agrawal
(Fri Nov 10 2023 - 16:22:09 MST)
Re: [AMMRL] Contour levels in Topspin
Bob Berno
(Sat Nov 11 2023 - 08:59:48 MST)
Re: [AMMRL] Contour levels in Topspin
Karel Klika
(Sun Nov 12 2023 - 10:41:54 MST)
Re: [AMMRL] Contour levels in Topspin
Karel Klika
(Sun Nov 12 2023 - 11:52:32 MST)
Re: [AMMRL] Contour levels in Topspin
Mike.Lumsden_at_dal.ca
(Wed Nov 15 2023 - 08:04:27 MST)
[AMMRL] position open: Director of NMR centre, Dept Chemistry University of Kentucky. Very nice place to live and wonderful colleagues!!
Anne-Frances Miller
(Wed Nov 15 2023 - 05:01:19 MST)
[AMMRL] Re position open: Director of NMR centre, Dept Chemistry University of Kentucky. Very nice place to live and wonderful colleagues!!
Anne-Frances Miller
(Wed Nov 15 2023 - 06:01:16 MST)
[AMMRL] Bruker LN2 Refill Kit Z165788
Mike.Lumsden_at_dal.ca
(Thu Nov 16 2023 - 11:58:45 MST)
Re: [AMMRL] Bruker LN2 Refill Kit Z165788
Josh Kurutz
(Fri Nov 17 2023 - 10:51:46 MST)
Re: [AMMRL] Bruker LN2 Refill Kit Z165788
Alvaro Herrera
(Mon Nov 27 2023 - 06:32:56 MST)
Re: [AMMRL] Bruker LN2 Refill Kit Z165788
Jeff Walton via groups.io
(Fri Nov 17 2023 - 20:38:44 MST)
Re: [AMMRL] Bruker LN2 Refill Kit Z165788
Ulrich
(Mon Nov 27 2023 - 08:18:23 MST)
[AMMRL] Oxford 800/63 magnet
Sara Whittaker
(Fri Nov 17 2023 - 04:53:10 MST)
[AMMRL] 4mm MAS3 Spinning Issues #Bruker #solids #Troubleshooting
Wendy Breyer
(Mon Nov 20 2023 - 16:30:33 MST)
Re: [AMMRL] 4mm MAS3 Spinning Issues #Bruker #solids #Troubleshooting
Dervisoglu, Riza
(Tue Nov 21 2023 - 00:48:28 MST)
Re: [AMMRL] 4mm MAS3 Spinning Issues #Bruker #solids #Troubleshooting
Ulrich
(Tue Nov 21 2023 - 02:09:19 MST)
Re: [AMMRL] 4mm MAS3 Spinning Issues #Bruker #solids #Troubleshooting
Madhu Basetti via groups.io
(Tue Nov 21 2023 - 02:40:50 MST)
Re: [AMMRL] 4mm MAS3 Spinning Issues #Bruker #solids #Troubleshooting
Struppe, Jochem via groups.io
(Tue Nov 21 2023 - 06:15:45 MST)
[AMMRL] B-ACS sample in Shim error
Pedro Aguiar
(Tue Nov 21 2023 - 07:46:07 MST)
Re: [AMMRL] B-ACS sample in Shim error
Martha Morton
(Tue Nov 21 2023 - 08:04:19 MST)
Re: [AMMRL] B-ACS sample in Shim error
Andre Dallmann
(Tue Nov 21 2023 - 08:12:43 MST)
Re: [AMMRL] B-ACS sample in Shim error
Spin-Doc
(Tue Nov 21 2023 - 12:35:55 MST)
[AMMRL] UConn-Storrs NMR Facility manager position
Gorbatyuk, Vitaliy
(Wed Nov 22 2023 - 13:37:08 MST)
[AMMRL] NMR Facility Position
Karen Ann Smith
(Mon Nov 27 2023 - 06:28:40 MST)
[AMMRL] ChemMagnetics/Varian Pencil Rotors
Justin Douglas
(Thu Nov 30 2023 - 11:34:03 MST)
Re: [AMMRL] ChemMagnetics/Varian Pencil Rotors
Michael Groves
(Thu Nov 30 2023 - 12:08:51 MST)
Last message date
:
Thu Nov 30 2023 - 11:33:25 MST
Archived on
: Fri Dec 01 2023 - 12:46:40 MST
50 messages
sort by
: [ thread ] [
author
] [
date
] [
subject
] [
attachment
]
Nearby
: [
Other mail archives
]
This archive was generated by
hypermail 2.4.0
: Fri Dec 01 2023 - 12:46:40 MST