Hi everybody,
It turns out that the solution was very simple. I just had to uncheck
the box "values may be edited".
This box can be found in the configuration, under "originator items".
When you first go into that screen, that box is grayed out and it's not
editable. In order to make it editable, you must select something in the
box labeled "set standard originator values for originator item". When I
selected "Account No." in that box ("Account No." is also set in the
"Originator Items" box at the top of the screen), then I was able to
uncheck the box labeled "values may be edited".
Now users are only able to select something from the list of
originators. They are not able to type anything. You can do something
fancier if you want to. You can define a regular expression in the
"Originator Items" box using wildcards. But the simple solution of only
allowing users to select something from a list is much easier and works
well for me.
Thanks to everybody that responded!
-Robert
On 2026-05-01 15:03, peterson_at_mbi.ucla.edu wrote:
> Hi everybody,
>
> I have a question about originators/account numbers in iconnmr:
>
> On our automated instruments our list of originators contains
> departmental account numbers that we use for recharge. We have things
> set up in iconnmr so that an Account No. is required in the title. In
> the configuration, "Originator items" is set to "Account No.", and in
> the User Manager, "Essential Originator" is checked. Users can click
> in the Account No. box when setting up the title and select their
> account number from the list, or they can type it.
>
> The problem is that if they type something, there's nothing to enforce
> that what they type is something in the list of originators. So when
> we do the billing we spend a lot of time correcting errors - typos or
> people using old invalid account numbers.
>
> Is there someway to set things up so that either:
> 1) Users are not able to type in that box, but only able to click
> something in the list.
> or
> 2) They are able to type in the box, but there's a mechanism to
> enforce that what they type is something from the list.
>
> Thanks in advance!
>
> -Robert
-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#3429): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/3429__;!!PvDODwlR4mBZyAb0!Vfj-hNm9sIj5LFynYjlfmVgiz7mlKm=
1EvzxRgyO8rCfQVNnocCnoALgM3k37eVjF8RBojy3ETRXuzzTWYqBHIASSEvVZ$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/119108241=
/7559972__;!!PvDODwlR4mBZyAb0!Vfj-hNm9sIj5LFynYjlfmVgiz7mlKm1EvzxRgyO8rCfQV=
NnocCnoALgM3k37eVjF8RBojy3ETRXuzzTWYqBHIBlK8vAQ$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-
Received on Thu May 07 2026 - 10:03:21 MST