Re: [AMMRL] Sample Jet Config

From: Gerd Gemmecker via groups.io <Gerd.Gemmecker=tum.de_at_groups.io>
Date: Tue, 10 Mar 2026 18:41:29 +0100

Am 10.03.26 um 16:00 schrieb Delk, Michael Joseph via groups.io:

> Hello,
> Received a request to utilize the Sample Jet that we have installed on the
> AV2 system we have.  It has been a couple years and
> other than perhaps a software upgrade to Topspin 3.2 pl7? nothing has changed.
> We get errors trying to use via Iconnmr as well as simple command line use i..e.
> SX EJ.  The complaint that seems to be the hold up is it states the BACS o
> is not configured via the tty port in CF.  I do not recall this being
> involved with CF before actually.  We have the sample changer connect via
> ethernet and accessed via HA page.
> Is there anyone with a Sample Jet with knowledge of the proper config they can
> share?  Perhaps in the uxnmr.info file?


Hi Mike,

we have a SampleJet installed on an AVII system, and I remember that it is
indeed configured in the cf (because we upgraded the computer yesterday
and had to re-install everything).

The "cf" asks for the tty port where our "BACS" is connected to (in our case tty05).
You can check it in the "uxnmr.info" file which is located in the topspinxyz/conf/instr/spect
directory, there should be an entry "Bruker Automatic Changer: device connected to
149.236.99.10:/dev/tty05" or similar.

This is an AV III running TS3.7/3.8, but I'd think it is very similar in previous versions,
I don't think we have ever changed that.

Good luck,

Gerd

--
PD Dr. Gerd Gemmecker
Bayerisches NMR-Zentrum
NAT School, TU München
Lichtenbergstr. 4
D-85747 Garching
Germany

Raum/Room 2108 / BNMRZ, E.O.Fischer-Str. 2
Tel. +49 (89) 289-52604
Fax +49 (89) 289-52669
e-mail: Gerd.Gemmecker_at_tum.de
Internet: http://www.gemmecker.de



-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#3286): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/3286__;!!PvDODwlR4mBZyAb0!T1rTAHl6XwXmmP3I8xu01S-UQfEx4Z=
XKN3IYbkQZbYGFDUKVapq0pB8p_fNACtqqfPZ7Sl_kD3rKUpDbqwBjcGH6dp8A$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/118242631=
/7559972__;!!PvDODwlR4mBZyAb0!T1rTAHl6XwXmmP3I8xu01S-UQfEx4ZXKN3IYbkQZbYGFD=
UKVapq0pB8p_fNACtqqfPZ7Sl_kD3rKUpDbqwBjcKosks0P$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-

Received on Tue Mar 10 2026 - 10:43:04 MST

This archive was generated by hypermail 2.4.0 : Wed Apr 01 2026 - 17:02:32 MST