RE: 19F chemical shift ranges

From: <Ian.MARSHALL_at_aventis.com>
Date: Tue, 27 Mar 2001 10:17:09 +0200

Mo
 
A couple of 'oldies but goodies' which you might like to check out (if they
are still available):
 
i) Annual Reports on NMR Spectroscopy Vol 10B, 1980. Edited by G.A.Webb,
published by Academic Press
 
ii) Progress in Nuclear Magnetic Resonance Spectroscopy Vol 7, 1971. Edited
by J.W.Emsley, J.Feeney, L.H.Sutcliffe, published by Pergamon Press
 
Both contain tables of 19F chemical shifts in a large number of different
chemical classes & ii) also contains some basic substituent chemical shift
information.
 
ACDLabs also offer 19F prediction & database tools to augment their 1H & 13C
packages however although we have the 1H & 13C modules I've no experience of
the 19F application
 
I hope this helps



Regards

Ian

+++++++++++++++++++++++++++++++++++++++++++++++++
Ian Marshall
NMR Spectroscopy
Aventis CropScience UK Ltd
Fyfield Road, Ongar, Essex, CM6 0HW

Direct Tel: +44 (0)1277 301196
Fax: +44 (0)1277 301188
e-mail: Ian.Marshall_at_aventis.com

The views and opinions of the author expressed herein and enclosed
information
do not necessarily state or reflect those of Aventis CropScience UK Ltd and

shall not be used for commercial purposes. Aventis CropScience UK Ltd shall

not be liable for any damages that may be sustained by using this
information,
whether direct, indirect, special, incidental or consequential, even if it
has been
advised of the possibility of such damages.


-----Original Message-----
> From: Mo Latif [mailto:Mo.Latif_at_terragen.co.uk]
> Sent: 26 March 2001 11:43
> To: ammrl_at_wwitch.unl.edu
> Subject: 19F chemical shift ranges



Greetings,

I'm working with some Fluorinated peptides, particularly incorporation of
5-Fluorotryptophan into a 15 residue peptide and am looking for pointers as
to where I could find a table of general regions of 19F chemical shifts or
in particular fluorinated aromatic amino acids.

Many thanks for any assistance you can provide.

Mo


Dr. Mohammed A. Latif
Cubist Pharmaceuticals (UK) Ltd
545 Ipswich Road
Slough
Berkshire SL1 4EQ
England UK
Tel: +44 (0) 1753 706 800 (switchboard)
Tel: +44 (0) 1753 706 713 (direct dial and voice mail)
Fax: +44 (0) 1753 706 808
mailto:mo.latif_at_terragen.co.uk <mailto:mo.latif_at_terragen.co.uk>
www.Cubist.com




This email message is for the sole use of the intended recipient(s) and may
contain confidential and privileged information. Its contents should not be
disclosed nor should it be given or copied to anyone. If you are not the
intended recipient, please contact the sender by reply email and destroy all
copies of the original message.

Cubist Pharmaceuticals (UK) Ltd makes no warranties of data transferred
using email and will not be liable for damages resulting from defective data
contained in this email.
Received on Tue Mar 27 2001 - 13:07:28 MST

This archive was generated by hypermail 2.4.0 : Sun Jun 04 2023 - 15:04:37 MST