Hi,
I am not sure which fuse would be in question? Here is a photo of the
AQS/3 back. The fuses in the upper right corner are good.
Regards,
Igor
On 26/01/2026 17:39, Philipp Hegemann via groups.io wrote:
> Hallo,
> Is it possible that a fuse is broken? Check on the back side if there
> is a LED not on. They are easily overseen…
> Greetings
> Philipp
>
>
>
> Dr. Philipp Hegemann
> Department fuer Chemie
> der Universitaet zu Koeln
> NMR-Abteilung
> Greinstr.4 <x-apple-data-detectors://3>
> D-50939 Koeln <x-apple-data-detectors://3> (Germany)
> (+49) (0)221 470 3874 <tel:(+49)%20221%20470%203874> (office – OC 117)
>
> http://www.nmr.chemie.uni-koeln.de/nmr.html
>
>
>> Am 26.01.2026 um 17:09 schrieb Igor Moudrakovski:
>>
>> Hello Everyone,
>>
>> I have a Bruker Avance III 400 MHz solid-state system circa 2010
>> (Cento5.11, Topspin 3.6.2), which developed over time a communication
>> problem between the SGUs and the amplifiers. The CF proceeds
>> seemingly without any problem, only to end up with an error message
>> ‘No connection between SGUs and amplifiers found! Acquisition will not
>> be possible. The wiring may be incorrect, or the emergency stop
>> signal may be active. Please check the hardware and do ‘cf’ again.’
>>
>> No visible problems with the hardware; all LEDs in front and back are
>> green, no warning/flashing lights, and no connections have changed
>> since the instrument was functioning. The ‘ha’ reveals no obvious
>> problems either.
>>
>> Last year, Bruker responded to the problem by replacing all the fans
>> and filters in AQS/3, as well as the amplifiers. That resulted in
>> about two months of stable work, but apparently didn’t solve the root
>> problem. Now the instrument is back to the state of ‘No connection
>> between SGUs and amplifiers…’ Numerous reboots didn’t move the problem.
>>
>> I would be very grateful to hear all your suggestions for resolving
>> the issue.
>> Thank you and best regards,
>>
>> Igor
>> --
>> Igor Moudrakovski, PhD
>> Max-Planck Institute for Solid State Research
>> Heisenbergstr. 1, 70569 Stuttgart, Germany
>> Office 711-689-1963
>> 400 NMR 711-689-1410
>> 600 NMR 711-689-1054
>>
>>
-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#3156): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/3156__;!!PvDODwlR4mBZyAb0!Wjhjs2OGVN8VFzYFyzeGqNHqs_poFb=
fzCnkznlfo5PfKof7a2LeKA69CbKv1KnXUqSPiBitQh555JFeIIFRqFbcwwuax$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/117471018=
/7559972__;!!PvDODwlR4mBZyAb0!Wjhjs2OGVN8VFzYFyzeGqNHqs_poFbfzCnkznlfo5PfKo=
f7a2LeKA69CbKv1KnXUqSPiBitQh555JFeIIFRqFcaus1KR$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-
Received on Tue Jan 27 2026 - 03:35:31 MST