Re: [AMMRL] 27Al background signal in iProbe

From: Quinn Kleerekoper <quinn.kleerekoper_at_gmail.com>
Date: Wed, 10 Jan 2024 18:06:23 -0600

Use topspin to process and type “apbk”. In command line .. should remove
it.

Automatic phasing and baseline correction..

On Wed, Jan 10, 2024 at 5:31 PM Tom Pratum <tkp9551_at_gmail.com> wrote:

> Hello All-
> We have a fairly new 400 MHz NEO Nano instrument with a broadband iProbe.
> One user is very interested in 27Al, and I note that in this probe there is
> a relatively significant 27Al background signal - I have seen 27Al
> background signals in pretty much every probe I have ever looked at. I have
> attached a plot of the signal (tuned empty probe) as acquired with a 2 usec
> pulse (around a 30 degree pulse at this power level), with the sw maxed out
> at 1.875 MHz, and 8 scans. The central component is around 11 kHz wide.
>
> I find the background signal relatively surprising due to the large number
> of components, and I am thinking the appearance could possible be due to
> one or more spin 5/2 powder patterns in which only the narrowest components
> appear due to how the spectrum was acquired, but really don’t know if that
> is the case. These components are not artifacts as they do move with the
> field.
>
> The user has some pretty broad signals they are interested in
> quantitating, and it would be good to remove the central component of this
> background signal if possible. I can think of a number of characteristics=
 -
> such as T2 and rf inhomogeneity - that could be used to remove the signal,
> but they would also likely affect the quantitation to some degree,
>
> Does anyone have any experience in removing this background signal they
> can suggest?
>
> Thanks in advance.
>
>
> Tom Pratum,
> Southern Oregon University
>
>
>
>
>
>
>


-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#917): https://urldefense.com/v3/__https://ammrl.groups.=
io/g/main/message/917__;!!PvDODwlR4mBZyAb0!VsIqyGQyu3kDnp6aYLqVdwMTxsLIMTFm=
BXsYenycjTUEzz9iFH6_KkRH3NYdkCVTip2Rfc1xxzshGfZzhNBvEqNlMw$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/103652483=
/7559972__;!!PvDODwlR4mBZyAb0!VsIqyGQyu3kDnp6aYLqVdwMTxsLIMTFmBXsYenycjTUEz=
z9iFH6_KkRH3NYdkCVTip2Rfc1xxzshGfZzhNBvNAWuRA$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-




Received on Wed Jan 10 2024 - 18:54:04 MST

This archive was generated by hypermail 2.4.0 : Thu Feb 01 2024 - 14:56:24 MST