Remote backup problem

From: Jeff de Ropp <jsderopp_at_ucdavis.edu>
Date: Tue, 02 Jan 2001 11:01:31 -0800

Dear All,
While trying a remote backup of a SGI from another SGI equipped with a DLT
drive, I get the error message:

select: protocol failure in circuit setup.
tar: tana: /dev/rmt/tps1d5 :I/O error.

(tana is the name of the local host where the tape drive is mounted). Both
SGIs are runing Irix 6.3. The DLT drive functions perfectly well in making
a backup of the local SGI. There is not (to my knowledge) any problem in
connecting between the SGIs - they telnet and ftp to one another fine. I
have followed the instructions to make the DLT a shared device, and the
remote SGI sees the DLT fine - it just won't make a back-up.

Any ideas on this problem would be welcomed. Please direct responses to me
and I will post a solution/summary.
Thanks,
Jeff


Jeff de Ropp
NMR Facility
UC Davis
One Shields Avenue
Davis CA 95616
jsderopp_at_ucdavis.edu
530-752-7677 office
530-752-6480 Lab
530-752-5682 Lab
530-752-8109 Fax
NMR Facility Web site URL is:
http://www.nmr.ucdavis.edu/
Received on Tue Jan 02 2001 - 18:05:58 MST

This archive was generated by hypermail 2.4.0 : Sun Jun 04 2023 - 14:19:24 MST