Dear Spinlanders,
For those of you who have to take part in proficiency testing (or would
like to, even if it's not mandatory for them), the interlaboratory comparison
organized by BASF and AQS Baden-Wuerttemberg might be of interest. It is open
for international participants! If you have any questions, please do not
hesitate to contact either me or the organizers.
Bet regards,
Christian
=================
AQS Baden-W-rttemberg in co-operation with BASF SE, Ludwigshafen,
is organising a proficiency test on the above-mentioned topic. The
mixture used in the PT will have the following components:
* 1,2,4,5-Tetrachlor-3-nitrobenzol (> 1 mg / 100 mg)
* 1,2,4,5-Tetramethylbenzol (> 1 mg / 100 mg)
* 2,4-Dichlorobenzotrifluorid (main component)
Each participant will get 1 sample. The sample mass will be around 200 mg.
Samples will be distributed in screw-capped GC vials.
Dates, deadlines and dispatch
* Deadline for registration: 15 February 2022
* Dispatch of samples: 15 March 2022
* Results submission: 05 April 2022
Dispatch of the samples will be undertaken by courier service. Within
Europe you will receive the samples usually one day after dispatch.
Sample analysis
Participants are free to choose a suitable analytical method. The
samples must be analysed in your own laboratory with your own personnel
and equipment. Subcontracting of the analysis is not permitted.
Result submission
Details will be provided with the samples.
Evaluation
Evaluation of participants' results will be achieved using a reference
value from sample formulation as an assigned value, if possible.
Otherwise, a robust mean of participants' data will be used. The
standard deviation of participants' data will be used as standard
deviation for proficiency assessment. The usual assessment for z-scores
will be used:
* |z| 2.0 successful
* 2.0 < |z| < 3.0 questionable
* |z| 3.0 not successful
Participation fee
Participation fee will be Euro 400 plus transportation costs
(express shipping from Germany).
Registration
Please use for registration the form provided on our webpage
www.aqsbw.de/en. The deadline for registration is 15 February 2022.
Terms and Conditions
Please note our general terms and conditions of business for the
execution of the PT, which can be downloaded from
www.aqsbw.de/pdf/agb_en.pdf. After registration you will receive an
e-mail for confirmation of receipt. With a second e-mail we will confirm
your application to the PT. If you do not receive one or both of the
e-mails, you are not registered.
If you have any questions, please do not hesitate to contact us:
AQS Baden-Württemberg, Bandtäle 2, 70569 Stuttgart, Germany
Phone: +49 711 685 65446
Telefax: +49 711 685 53769
E-Mail: <mailto:info_at_aqsbw.de> info_at_aqsbw.de
Contact: Dr. Frank Baumeister, Dr. Michael Koch
Best regards,
Dr. Michael Koch, Scientific director AQS
Dr. Frank Baumeister, PT coordinator
AQS Baden-Württemberg
Institut für Siedlungswasserbau, Wassergüte- und
Abfallwirtschaft / Institute for Sanitary Engineering, Water Quality and Solid Waste Management
Universität Stuttgart / University of Stuttgart
Bandtäle 2
70569 Stuttgart
Tel.: +49 (0)711 685-65446
Fax: +49 (0)711 685-53769
==================================================
Dr. Christian Adam
Competence Center Analytics
RAA Our Knowledge - Your Advantage
RAA Unser Wissen – Ihr Vorteil
RAA 我们的知识 – 您们的优势
#GernPerDu #CallMeByMyFirstName
* Call me in <callto:christian.k.adam_at_basf.com> Teams
* Chat with me in <msteams:l/chat/0/0?users=christian.k.adam_at_basf.com> Teams
Phone: +49 621 60-58670, Mobile: +49 172 6352576, Fax: +49 621 66-58670, Email: christian.k.adam_at_basf.com
Postal Address: BASF SE, RAA/AR - B009, Carl-Bosch-Strasse 38, 67056 Ludwigshafen am Rhein, Deutschland
BASF SE, Registered Office: 67056 Ludwigshafen, Germany
Registration Court: Amtsgericht Ludwigshafen, Registration No.: HRB 6000
Chairman of the Supervisory Board: Kurt Bock
Board of Executive Directors:
Martin Brudermueller, Chairman; Hans-Ulrich Engel, Vice Chairman;
Saori Dubourg, Michael Heinz, Markus Kamieth, Melanie Maas-Brunner
Information on data protection can be found here: https://www.basf.com/global/en/legal/data-protection-at-basf.html
Received on Fri Feb 04 2022 - 03:10:40 MST