Hi Laird and AMMRL,

Thanks, Laird, for the suggestion and incredibly helpful subsequent emails.
I had worried about potential issues having TopSpin write to a remotely
shared folder, but Laird is right: it works perfectly and avoids SMB. It’s
also then easier to share the data folder to our backup server, as it can be
shared through Windows without any additional work.

One other note: I’d initially set up the VM to use 4 vCPUs but had
the rare crash when booting. After trying various suggested workarounds on
the internet to no avail, I lowered the CPU count to 1 and disabled “I/O APIC”,
and it has since been stable. TopSpin 2.1 runs just fine on one-core of a modern CPU 😊

Best,
Sameer

--
Sameer Al-Abdul-Wahid, Ph.D.

Manager, Nuclear Magnetic Resonance Centre <http://nmr.uoguelph.ca/>
University of Guelph
519-824-4120 x58914 / s.wahid_at_uoguelph.ca

> From: main_at_ammrl.groups.io on behalf of Laird Trimble via groups.io
> Date: Tuesday, December 16, 2025 at 09:10
> To: main_at_ammrl.groups.io <main_at_ammrl.groups.io>
> Subject: Re: [AMMRL] Replacing an AVANCE II PC in 2025

Hi Sameer,

For sharing the data from the guest to host OS, why not use VirtualBox’s
shared folder mechanism? This would avoid the use of the potential security
issues of old versions of SMB.

Cheers,

Laird

Laird A. Trimble, Ph.D.
President, Trimble Analytical Services Ltd.
laird.trimble_at_trimbleanalyticalservices.com
1-613-286-2799


On Dec 15, 2025, at 5:12 PM, Sameer Al-Abdul-Wahid via groups.io wrote:

Hi AMMRL,

Thanks to Greg, Laird, Ronald, Serge, Bob, Sebastian, we’re back up
and running. The information below would not have been possible without their
help!

I should have clarified: we did not have recent image to restore from, and
I was not able to restore Bruker’s clone CD (from install) to a
Virtualbox VM. That being said, I’m happy to report two working
options:

TopSpin 3.2 on Windows 11

Bruker’s download page
<https://www.bruker.com/protected/en/services/software-downloads/nmr/software/topspin-archive.html>
has the NT Toolkit 2 CD, containing the OpenText NFS Solo 14 server which can be installed on
Windows 11. After installing TopSpin 3.2, the CCU downloaded diskless and “cf”
worked properly. I didn’t test this setup any further, as I eventually managed to get
TopSpin 2.1 running and our users preferred that route.

TopSpin 2.1 on CentOS 5

Install Virtualbox 7.2.4 and create a CentOS 5 < https://vault.centos.org/5.11/isos/x86_64/>
VM. Set the first NIC to NAT, using the MAC address of the old PC, and connect it to
the campus network. Set the second NIC to "Bridged Adapter” and connect it
to the spectrometer. Install CentOS 5 with the GNOME desktop.

To install/update packages with yum, first edit /etc/yum/repos.d/CentOS-Base.repo, by:

  *
Deleting all “mirrorlist” lines
  *
Uncommenting all “baseurl” lines
  *
Replacing http://mirror.centos.org/centos/$releasever/ with
http://archive.kernel.org/centos-vault/5.11/ because the
versions at “centos.org” seem to require a
newer version of SSL than supported by CentOS 5.
 *


Packages can now be updated, and a number of other packages should be installed
before proceeding:

sudo yum -y update
sudo yum install xinetd dhcp tftp tftp-server bootparamd gcc gcc-c++ glibc-devel glibc-headers kernel-headers libXmu.so.6 libXp libXpm.so.4 openmotif samba

The Bruker packages
<https://repo-bbio.bruker.com/CentOS/5/Bruker-Addon/repoview/index.html>
or RPM-GPG-KEY<https://repo-bbio.bruker.com/CentOS/RPM-GPG-KEY-Bruker-AddOn-support>
cannot be downloaded in the normal way, apparently due to the SSL issue.
Download the key and packages listed below from the links above, then install
them one-by-one in the order listed:

sudo rpm --import RPM-GPG-KEY-Bruker-AddOn-support.txt
sudo rpm -ivh cups-pdf-2.6.1-4.el5.brk.x86_64.rpm
sudo rpm -ivh bruker-lockdown-session-1.0-0.el5.brk.noarch.rpm
sudo rpm -ivh bruker-topspin-environ-1.0-13.el5.brk.x86_64.rpm
sudo rpm -ivh bruker-compatlibs-1.3-7.el5.brk.x86_64.rpm
sudo rpm -ivh bruker-gdm-theme-1.3-1.el5.brk.noarch.rpm
sudo rpm -ivh bruker-acquisition-environ-1.0-2.el5.brk.noarch.rpm

Install TopSpin 2.1, then disable iptables and fix a diskless permissions issue:

sudo /sbin/service iptables stop
sudo /sbin/chkconfig iptables off
sudo chmod a+w /usr/diskless/clients/spect/lock/*

Reboot the CCU, do an nmr_restore from an old backup, run ‘cf’,
and collect data.

I’ve since changed the first NIC from NAT to “Host-Only Adapter”,
so the VM is not connected to the Internet. At the moment, I’m using SMB to
get data from the VM to the campus network, which does require enabling SMB 1.0/CIFS
File Sharing Support in Windows and accepting/mitigating the security risks that come
with that.

Best,
Sameer
--
Sameer Al-Abdul-Wahid, Ph.D.
Manager, Nuclear Magnetic Resonance Centre<http://nmr.uoguelph.ca/>
University of Guelph
519-824-4120 x58914 / s.wahid_at_uoguelph.ca


> From: Sameer Al-Abdul-Wahid <s.wahid_at_uoguelph.ca>
> Date: Wednesday, December 10, 2025 at 15:41
> To: Main <main_at_ammrl.groups.io>
> Subject: Replacing an AVANCE II PC in 2025

Hello AMMRL,

Our AVANCE II computer died and I’m trying to replace it.

At the suggestions of others, I’ve started down the route of setting
up VirtualBox on our Windows 11 machine, so I can create a CentOS 5 VM to run
TopSpin 2.1. It’s a “two steps forward, one step back”
process - for example, I can install CentOS 5, but doing an update of the
(non-Bruker) packages requires a workaround.

Before I go too far down this path, I thought I’d ask the collective
wisdom - what have others done here? Are there newer Linux OSs that could
work here? Using Windows seems to rely on needing an NFS server that I cannot
seem to find.

Our system could in theory support TopSpin 3.2 so I’d be open an
option that required me to use 3.2 as well.

Thanks for your time,
Sameer

--
Sameer Al-Abdul-Wahid, Ph.D.
Manager, Nuclear Magnetic Resonance Centre<http://nmr.uoguelph.ca/>
University of Guelph
519-824-4120 x58914 / s.wahid_at_uoguelph.ca


-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#3075): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/3075__;!!PvDODwlR4mBZyAb0!RhVYDKhLS_Mu46NBZatJXV7JosXKCP=
bES5E6Dfr0n_wJ8UNHvspgd-Y5-zJo95utQ13I8Atdb-cHIeh8gJHxRvPNpPAA$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/116718929=
/7559972__;!!PvDODwlR4mBZyAb0!RhVYDKhLS_Mu46NBZatJXV7JosXKCPbES5E6Dfr0n_wJ8=
UNHvspgd-Y5-zJo95utQ13I8Atdb-cHIeh8gJHxRjNcA2xc$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-



Received on Fri Dec 19 2025 - 05:49:20 MST

This archive was generated by hypermail 2.4.0 : Thu Jan 01 2026 - 15:24:06 MST