Dear Colleagues:
*Please REPLY TO SENDER via link at the bottom of the email if interested*
We are in the process of cleaning out some of our older NMR instrumentation
and related equipment. The list below is available for interested parties.
*
Oxford 600 MHz magnet with DD2 Console, AirJet XR, FTS system, autosampler,
MAS unit, VT, autotuning unit, pneumatic routers, RF front end, He and N2 meters,
and charging rods. The NMR was operational when it was brought down.
* Probes for the 600 include
* Varian (Agilent) One NMR Probe-PT (G7426-60003)
* Varian Narrow Bore VT stack solids assembly
* Varian High Field TR/PFG 5mm triple resonance HCN probe
* Varian 600 TR/PFG 5 mm HCN probe
* NCC IDTGX 600-5 5 mm indirect triple resonance probe
* Varian 600 gHX Nano probe
* Varian 600 SW/PFG 5mm triple resonance probe
*
Oxford 500 MHz magnet with DD2 console, VNMRS console, Unity console, RF handlers
for each console, tachometer for HRMS, shim stacks, charging rods (also rods for
a 400 magnet), and an Inova 500 TRIAX upper barrel. The NMR was operational when it was brought down.
* Probes for the 500 include
* Varian 964682 5mm broadband (50-202 MHz)
* Varian 968055-01 5mm 1H/19F probe
* Nalorac DBG500-5EHT 5mm HX broadband direct probe*
* Microflow triple resonance HCN
* Nalorac ID500-8 indirect 8mm HX probe*
* Varian 500gHX Nano*
* Nalorac IDQ3G500-5HT 5mm quad resonance*
* Nalorac IDTG500-5HT 5mm triple resonance*
* Varian DBG500-5ETF XH 5mm
* Varian TR/PFG 5mm HCN triple resonance indirect
* Varian 968462 5mm broadband (50-202MHz)
* Varian AutoX DBPFG dual broadband 5mm
* Varian 992430-1 5mm HCN triple resonance probe
* Additional probes from other instruments
* Otsuka PRB400-322 broadband
* Chemagnetics CMP400-VP3-3013 Triple resonance HCN?
* Chemagnetics CMP400SRNS-2184 1H
* Otsuka PRB400-310 Triple resonance wide bore HXY*
* Doty Scientific Inc DSI-368 (400 MHz)
* Otsuka SPC400-456*
* Chemagnetics CMP400VP2-3008
* Spectrospin VSP300-SB 5mm broadband
* Nalorac 4N300-50x NB+ 5mm HFCP*
* Varian 969551-00 HX (300 MHz) 5 mm broadband (30-122 MHz)
* Varian 991548-02 (300 MHz) 5 mm HFCP
Please let me know by September 6 if you are interested in any of these items.
I will include your information with our surplus pickup request. We will need
to work through our university’s surplus process, but it is not particularly
difficult as these things go. I will be available to help coordinate with Surplus
if you (or they) have any questions. Much of the equipment predates our time
with the lab, but we will do our best to answer any instrument history questions.
Thank you,
Billy Schmuck
**
*Billy SCHMUCK*
Reactor Operations Engineer
Nuclear Science Center
Washington State University
(509) 335-2354
Email: bschmuck_at_wsu.edu
nsc.wsu.edu
-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#3726): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/3726__;!!PvDODwlR4mBZyAb0!V3e0bTiImwAnembX04GIqzoPDQeB5-=
VGmaoy_JOADsD_0wga5DFOZvBN8lGgAInyh744B43183_tVZdFsckylYyhxamy$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/120978641=
/7559972__;!!PvDODwlR4mBZyAb0!V3e0bTiImwAnembX04GIqzoPDQeB5-VGmaoy_JOADsD_0=
wga5DFOZvBN8lGgAInyh744B43183_tVZdFsckylbud1XrL$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-
Received on Fri Aug 28 2026 - 13:55:11 MST