[AMMRL] Varian Mercury 400 Not Spinning #Hardware #NMR_Liquids #Troubleshooting #varian #VarianAgilent

From: foglein via groups.io <foglein=rowan.edu_at_groups.io>
Date: Thu, 06 Aug 2026 07:03:04 -0700

We have a Varian Mercury plus 400 MHz system with an Oxford magnet. Mostly,
this system sits idle waiting until our newer Bruker system becomes inoperable.
Yesterday, we were unable to get the sample to spin at all. I've removed and
cleaned the upper barrel, removed and checked the probe for debris or broken
tubes that would bind the spinning, and tried multiple spinners that have worked
in the past, making sure they were clean and undamaged. I am unsure what to
check next, so I would appreciate any advice.

Best,

Jon

--
Mr. Jonathan Foglein
Instrument Coordinator/
Chemical Hygiene Officer

Rowan University
Department of Chemistry & Biochemistry
Science Hall, Room 345
201 Mullica Hill Road
Glassboro, NJ 08028

Phone: 856-256-5456
Email: foglein_at_rowan.edu


-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#3669): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/3669__;!!PvDODwlR4mBZyAb0!XIj426HDuphtoKMruySPKQksyf0XR5=
B8kBKunNNoOHiLhEBpg8AXHimv_AQM9WJ5DluLE5blybklQFfJKIaX5Ou7yFao$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/120628631=
/7559972__;!!PvDODwlR4mBZyAb0!XIj426HDuphtoKMruySPKQksyf0XR5B8kBKunNNoOHiLh=
EBpg8AXHimv_AQM9WJ5DluLE5blybklQFfJKIaX5AfPUkYu$
Mute #nmr_liquids:https://urldefense.com/v3/__https://ammrl.groups.io/g/mai=
n/mutehashtag/nmr_liquids__;!!PvDODwlR4mBZyAb0!XIj426HDuphtoKMruySPKQksyf0X=
R5B8kBKunNNoOHiLhEBpg8AXHimv_AQM9WJ5DluLE5blybklQFfJKIaX5Ev677kv$
Mute #troubleshooting:https://urldefense.com/v3/__https://ammrl.groups.io/g=
/main/mutehashtag/troubleshooting__;!!PvDODwlR4mBZyAb0!XIj426HDuphtoKMruySP=
KQksyf0XR5B8kBKunNNoOHiLhEBpg8AXHimv_AQM9WJ5DluLE5blybklQFfJKIaX5GPHstCq$
Mute #varian:https://urldefense.com/v3/__https://ammrl.groups.io/g/main/mut=
ehashtag/varian__;!!PvDODwlR4mBZyAb0!XIj426HDuphtoKMruySPKQksyf0XR5B8kBKunN=
NoOHiLhEBpg8AXHimv_AQM9WJ5DluLE5blybklQFfJKIaX5EA_jn-s$
Mute #varianagilent:https://urldefense.com/v3/__https://ammrl.groups.io/g/m=
ain/mutehashtag/varianagilent__;!!PvDODwlR4mBZyAb0!XIj426HDuphtoKMruySPKQks=
yf0XR5B8kBKunNNoOHiLhEBpg8AXHimv_AQM9WJ5DluLE5blybklQFfJKIaX5MZsLumQ$
Mute #hardware:https://urldefense.com/v3/__https://ammrl.groups.io/g/main/m=
utehashtag/hardware__;!!PvDODwlR4mBZyAb0!XIj426HDuphtoKMruySPKQksyf0XR5B8kB=
KunNNoOHiLhEBpg8AXHimv_AQM9WJ5DluLE5blybklQFfJKIaX5JHfC8MW$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-




Received on Thu Aug 06 2026 - 08:47:17 MST

This archive was generated by hypermail 2.4.0 : Tue Sep 01 2026 - 13:53:27 MST