Hi Beth,

we are using the reinforced PVC tube (softenned PVC both inner part as well
as the outer part) like this
https://www.gumex.cz/h/1125-hadice-na-pitnou-vodu-a-tekute-pozivatiny-01283?Filter=True


either 10/14mm diam. or 16/22 diam. (inner/outer) for different magnets.

This kind of tube works well, once upon a time it breaks, so we cut a new
piece. At a price of ~ 30 CZK/m it does not matter.

Cheers,

       Jan

---------------------------------------------------------

Jan Lang
Associate Professor
Charles University
Faculty of Mathematics & Physics
Department of Low Temperature Physics
V Holesovickach 747/2
CZ-180 00 Prague 8
Czech Republic

Tel.: +420 221912889

http://nmr.mff.cuni.cz

> From: main_at_ammrl.groups.io On Behalf Of Beth Moscato
> Sent: Monday, August 26, 2024 3:37 PM
> To: main_at_ammrl.groups.io
> Subject: [AMMRL] Tubing for N2 fill exhaust?

Hi all

This is a ridiculously stupid question, but my Google-fu is currently failing me.

Our exhaust tubing (the type you put on the N2 exhaust port during nitrogen
fills so it doesn’t spit everywhere – we have Oxfords and
a Bruker, all of them seem to be the standard dimension) is ratty, and I am
currently trying to replace it. I’m measuring an inner diameter of
1.6 cm / 0.66”. It seems like the sort of thing I should easily be
able to order on Aldrich or Fisher, but I’m failing to find any
flexible tubing (rubber or otherwise) of that dimension.

Does anyone have a link to a supplier of the correct ID of tubing? Preferably
something that I don’t need to buy in 100’ coils.

This seems like it should be a ridiculously simple thing to find, but I spent
awhile searching and didn’t have any luck.

Thank you!

Beth


-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#1566): https://urldefense.com/v3/__https://ammrl.groups=
.io/g/main/message/1566__;!!PvDODwlR4mBZyAb0!WOWgRwAuXcfmaw9YVUnuWj2hn42x_C=
0xGytlnTuujIDOwkO74QBY2qcbVOYQIBxW-TjS0fF8sU0ZkBZmf5Eu$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/108103713=
/7559972__;!!PvDODwlR4mBZyAb0!WOWgRwAuXcfmaw9YVUnuWj2hn42x_C0xGytlnTuujIDOw=
kO74QBY2qcbVOYQIBxW-TjS0fF8sU0ZkAySiWvU$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-




Received on Thu Aug 29 2024 - 06:06:42 MST

This archive was generated by hypermail 2.4.0 : Sun Sep 01 2024 - 15:22:33 MST