Dear fellows Varian VT probe users,
I am not sure to what extent it is in line with "ammrl" policy but I
would like to start a discussion on the VT connectors on Varian probes.
In our laboratory the connector is a permanent source of troubles on
otherwise excellent probes (and spectrometers).
If you look at the recently introduced AutoX probe, you see the same
obsolete connector used again.
I cannot believe that ours is the only laboratory complaining about
these connectors?
Has anybody found a good solution eliminating the losses of VT control
(besides using rubber bands)?
With the best regards,
Jan Schraml
*******************************************************
Prof. Jan Schraml, DrSc
NMR laboratory, Head
Institute of Chemical Process Fundamentals
Academy of Sciences, Czech Republic
Rozvojova 135
Prague 6, 165 02
Czech Republic
Tel: (+420) 220 390 315 or (+420) 296 780 315
Fax: (+420) 220 390 357 or (+420) 296 780 357
or (+420) 220 92 06 61 - central office
e-mail: schraml_at_icpf.cas.cz
-----Original Message-----
> From: J.M. Ernsting [mailto:janm_at_science.uva.nl]
> Sent: Thursday, August 26, 2004 10:02 AM
> To: ammrl_at_ammrl.org
> Subject: VT-connector
Dear Varian users,
We have a probe of our Inova 500 where the VT- connector on the probe is damaged
we like to replace the connector does any one know a supplier of these connectors.
With best regards / met vriendelijke groeten
Jan Meine Ernsting
************************************
* Ing. J.M. Ernsting
* University of Amsterdam
* Faculty of Science
*Institute of Molecular Chemistry
* NMR Department
* Nw. Achtergracht 166
* 1018 WV AMSTERDAM
* The Netherlands
*
* phone: +31.20.525 6441
* fax: +31.20.525 6456
************************************
Received on Fri Aug 27 2004 - 18:32:25 MST