[AMMRL] Help Needed: Broad/Missing ¹³C NMR Signals
Muhammad Adil Raees via groups.io
(Wed Oct 01 2025 - 07:38:00 MST)
Re: [AMMRL] Help Needed: Broad/Missing ¹³C NMR Signals
Shore, Jay via groups.io
(Wed Oct 01 2025 - 07:57:44 MST)
Re: [AMMRL] Help Needed: Broad/Missing ¹³C NMR Signals
Karel Klika via groups.io
(Wed Oct 01 2025 - 08:03:17 MST)
Re: [AMMRL] Help Needed: Broad/Missing ¹³C NMR Signals
Molinski, Tadeusz via groups.io
(Wed Oct 01 2025 - 10:37:29 MST)
Re: [AMMRL] Help Needed: Broad/Missing ¹³C NMR Signals
Andre Dallmann via groups.io
(Wed Oct 01 2025 - 08:04:26 MST)
Re: [AMMRL] Help Needed: Broad/Missing ¹³C NMR Signals
Volodymyr Semeniuchenko via groups.io
(Wed Oct 01 2025 - 08:13:15 MST)
Re: [AMMRL] Help Needed: Broad/Missing ¹³C NMR Signals
Karel Klika via groups.io
(Wed Oct 01 2025 - 08:15:40 MST)
Re: [AMMRL] Help Needed: Broad/Missing ¹³C NMR Signals
Anklin, Clemens via groups.io
(Wed Oct 01 2025 - 08:24:20 MST)
Re: [AMMRL] Help Needed: Broad/Missing ¹³C NMR Signals
Platz Hirsch via groups.io
(Wed Oct 01 2025 - 10:55:43 MST)
Re: [AMMRL] Help Needed: Broad/Missing ¹³C NMR Signals
Molinski, Tadeusz via groups.io
(Wed Oct 01 2025 - 14:39:26 MST)
[AMMRL] Strange 1H spectrum to share. Care to guess the cause?
brcherry via groups.io
(Wed Oct 01 2025 - 12:19:43 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
Wendy Breyer via groups.io
(Wed Oct 01 2025 - 12:41:15 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
jon via groups.io
(Wed Oct 01 2025 - 12:54:46 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
Spin-Doc
(Wed Oct 01 2025 - 14:01:58 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
Ralifo, Paul S. via groups.io
(Wed Oct 01 2025 - 12:47:19 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
Anklin, Clemens via groups.io
(Wed Oct 01 2025 - 12:49:57 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
brcherry via groups.io
(Wed Oct 01 2025 - 14:04:13 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
Karel Klika via groups.io
(Wed Oct 01 2025 - 12:55:23 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
Huadong Zeng via groups.io
(Wed Oct 01 2025 - 17:56:46 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
Vuckovic, Ivan, Ph.D. via groups.io
(Wed Oct 01 2025 - 13:34:04 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
Michael Groves via groups.io
(Wed Oct 01 2025 - 13:36:52 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
John Decatur via groups.io
(Wed Oct 01 2025 - 20:14:16 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
David Richardson via groups.io
(Wed Oct 01 2025 - 13:55:49 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
gafacey via groups.io
(Wed Oct 01 2025 - 18:53:44 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
Gerd Gemmecker via groups.io
(Thu Oct 02 2025 - 01:33:10 MST)
Re: [AMMRL] Strange 1H spectrum to share. Care to guess the cause?
Alex Paterson via groups.io
(Thu Oct 02 2025 - 05:03:05 MST)
[AMMRL] Tuning rods pinned?
Baleja, James D via groups.io
(Wed Oct 01 2025 - 14:53:29 MST)
Re: [AMMRL] Tuning rods pinned?
Anklin, Clemens via groups.io
(Thu Oct 02 2025 - 05:28:58 MST)
Re: [AMMRL] Tuning rods pinned?
Ezell, Ed via groups.io
(Thu Oct 02 2025 - 09:28:25 MST)
Re: [AMMRL] Tuning rods pinned?
Baleja, James D via groups.io
(Thu Oct 02 2025 - 10:01:11 MST)
Re: [AMMRL] Tuning rods pinned?
Roberts, Jessica via groups.io
(Tue Oct 07 2025 - 04:43:19 MST)
Re: [AMMRL] Tuning rods pinned?
Ezell, Ed via groups.io
(Tue Oct 07 2025 - 07:12:31 MST)
Re: [AMMRL] Tuning rods pinned?
Karel Klika via groups.io
(Thu Oct 02 2025 - 06:15:39 MST)
Re: [AMMRL] Tuning rods pinned?
Perry Pellechia via groups.io
(Wed Oct 01 2025 - 18:36:54 MST)
Re: [AMMRL] Tuning rods pinned?
Matthias Brandl via groups.io
(Thu Oct 02 2025 - 01:32:05 MST)
Re: [AMMRL] Tuning rods pinned?
PLscientific
(Thu Oct 02 2025 - 15:51:10 MST)
Re: [AMMRL] Tuning rods pinned?
Baleja, James D via groups.io
(Fri Oct 03 2025 - 12:39:41 MST)
Re: [AMMRL] Tuning rods pinned?
nadia beepath via groups.io
(Sat Oct 04 2025 - 13:25:20 MST)
Re: [AMMRL] Tuning rods pinned?
nadia beepath via groups.io
(Tue Oct 07 2025 - 00:08:28 MST)
Re: [AMMRL] Tuning rods pinned?
Karel Klika via groups.io
(Fri Oct 03 2025 - 13:06:29 MST)
Re: [AMMRL] Tuning rods pinned?
Michael Groves via groups.io
(Fri Oct 03 2025 - 14:04:07 MST)
Re: [AMMRL] Tuning rods pinned?
Karel Klika via groups.io
(Mon Oct 06 2025 - 10:24:29 MST)
[AMMRL] TXI probe removal advice
Baleja, James D via groups.io
(Thu Oct 23 2025 - 08:37:18 MST)
Re: [AMMRL] TXI probe removal advice
D'Anciaes Almeida Silva, Igor via groups.io
(Thu Oct 23 2025 - 08:48:42 MST)
Re: [AMMRL] TXI probe removal advice
Michael Groves via groups.io
(Thu Oct 23 2025 - 09:02:52 MST)
Re: [AMMRL] TXI probe removal advice
Gary Thompson via groups.io
(Thu Oct 23 2025 - 09:29:37 MST)
Re: [AMMRL] TXI probe removal advice
Josh Kurutz via groups.io
(Thu Oct 23 2025 - 10:00:55 MST)
Re: [AMMRL] TXI probe removal advice
Baleja, James D via groups.io
(Thu Oct 23 2025 - 10:34:48 MST)
Re: [AMMRL] TXI probe removal advice
Michael Groves via groups.io
(Thu Oct 23 2025 - 11:13:04 MST)
Re: [AMMRL] TXI probe removal advice
Indrek Reile via groups.io
(Fri Oct 24 2025 - 05:47:00 MST)
Re: [AMMRL] TXI probe removal advice
Karel Klika via groups.io
(Fri Oct 24 2025 - 06:08:36 MST)
Re: [AMMRL] Tuning rods pinned?
Jones, David (Pharm) via groups.io
(Mon Oct 06 2025 - 15:49:44 MST)
Re: [AMMRL] compressed N2 gas vs compressed Air
Anklin, Clemens via groups.io
(Thu Oct 02 2025 - 06:12:35 MST)
[AMMRL] Receiver board problem
Wang, Tianzhi via groups.io
(Thu Oct 02 2025 - 11:56:01 MST)
[AMMRL] AMMRL: Floor types
Ian Luck via groups.io
(Thu Oct 02 2025 - 17:11:05 MST)
[AMMRL] Bruker Avance I Power outage #Bruker #Hardware
joern.droste via groups.io
(Mon Oct 06 2025 - 06:21:39 MST)
Re: [AMMRL] Bruker Avance I Power outage #Bruker #Hardware
Matthias Brandl via groups.io
(Mon Oct 06 2025 - 07:49:44 MST)
Re: [AMMRL] Bruker Avance I Power outage #Bruker #Hardware
Justine CORREIA via groups.io
(Mon Oct 06 2025 - 08:18:25 MST)
Re: [AMMRL] Bruker Avance I Power outage #Bruker #Hardware
Michael Groves via groups.io
(Mon Oct 06 2025 - 08:21:13 MST)
Re: [extern] Re: [AMMRL] Bruker Avance I Power outage #Bruker #Hardware
joern.droste via groups.io
(Mon Oct 06 2025 - 08:46:46 MST)
Re: [extern] Re: [AMMRL] Bruker Avance I Power outage #Bruker #Hardware
Spin-Doc
(Mon Oct 06 2025 - 10:07:44 MST)
Re: [extern] Re: [AMMRL] Bruker Avance I Power outage #Bruker #Hardware
Matthias Brandl via groups.io
(Tue Oct 07 2025 - 00:33:52 MST)
[AMMRL] Prodigy Probe Startup State? No probe??
Anne Rachupka via groups.io
(Mon Oct 06 2025 - 10:29:48 MST)
Re: [AMMRL] Prodigy Probe Startup State? No probe??
Sham, Shing via groups.io
(Mon Oct 06 2025 - 11:27:17 MST)
Re: [AMMRL] Prodigy Probe Startup State? No probe??
Anne Rachupka via groups.io
(Mon Oct 06 2025 - 14:59:59 MST)
Re: [AMMRL] Prodigy Probe Startup State? No probe??
Spin-Doc
(Mon Oct 06 2025 - 17:19:50 MST)
[AMMRL] find z0 problem on INOVA 400
Zhao, Chunqing via groups.io
(Mon Oct 06 2025 - 11:46:03 MST)
Re: [AMMRL] find z0 problem on INOVA 400
johnhahn cazent.com
(Mon Oct 06 2025 - 14:45:49 MST)
Re: [AMMRL] find z0 problem on INOVA 400
Zhao, Chunqing via groups.io
(Tue Oct 07 2025 - 11:51:40 MST)
Re: [AMMRL] find z0 problem on INOVA 400
johnhahn cazent.com
(Tue Oct 07 2025 - 12:43:05 MST)
Re: [AMMRL] find z0 problem on INOVA 400
Zhao, Chunqing via groups.io
(Tue Oct 07 2025 - 13:37:33 MST)
Re: [AMMRL] find z0 problem on INOVA 400
johnhahn cazent.com
(Tue Oct 07 2025 - 17:08:21 MST)
Re: [AMMRL] find z0 problem on INOVA 400
Spin-Doc
(Mon Oct 06 2025 - 17:25:50 MST)
Re: [AMMRL] find z0 problem on INOVA 400
Zhao, Chunqing via groups.io
(Tue Oct 07 2025 - 11:21:04 MST)
Re: [AMMRL] find z0 problem on INOVA 400
johnhahn cazent.com
(Wed Oct 08 2025 - 05:12:10 MST)
Re: [AMMRL] find z0 problem on INOVA 400
Zhao, Chunqing via groups.io
(Wed Oct 08 2025 - 07:14:01 MST)
Re: [SteeringCmte] [AMMRL] find z0 problem on INOVA 400
ter Horst, Marc A. via groups.io
(Wed Oct 08 2025 - 07:24:35 MST)
Re: [AMMRL] find z0 problem on INOVA 400
Zhao, Chunqing via groups.io
(Tue Oct 14 2025 - 09:16:53 MST)
[AMMRL] Seemingly sporadic tuning/matching errors
Roberts, Jessica via groups.io
(Mon Oct 06 2025 - 09:37:19 MST)
[AMMRL] Varian Ref Gen Board MR400
uakanbur via groups.io
(Tue Oct 07 2025 - 06:51:43 MST)
Re: [AMMRL] Varian Ref Gen Board MR400
Spin-Doc
(Tue Oct 07 2025 - 10:45:08 MST)
[AMMRL] Lithium compound for pulse calibration?
Wendy Breyer via groups.io
(Tue Oct 07 2025 - 08:00:56 MST)
Re: [AMMRL] Lithium compound for pulse calibration?
Anklin, Clemens via groups.io
(Tue Oct 07 2025 - 08:25:04 MST)
Re: [AMMRL] Lithium compound for pulse calibration?
GOBET Mallory via groups.io
(Tue Oct 07 2025 - 12:43:14 MST)
[AMMRL] We're Hiring: CSICOMP NMR Facility at the University of Toronto
Darcy Burns via groups.io
(Tue Oct 07 2025 - 08:37:42 MST)
[AMMRL] IUPAC FAIRSpec: Your input and possible involvement requested
Robert Hanson via groups.io
(Tue Oct 07 2025 - 09:50:25 MST)
[AMMRL] AMMRL: Quick Connectors for Varian Protune Probes
Jerry Hu via groups.io
(Thu Oct 09 2025 - 09:51:42 MST)
Re: [AMMRL] AMMRL: Quick Connectors for Varian Protune Probes
Lin, Penghui via groups.io
(Thu Oct 09 2025 - 12:00:47 MST)
[AMMRL] EPR: ESR900 Cryostat brass washers
Kenneth Sharp-Knott via groups.io
(Mon Oct 13 2025 - 07:29:19 MST)
Re: [AMMRL] EPR: ESR900 Cryostat brass washers
Charles Hanson via groups.io
(Mon Oct 13 2025 - 15:18:05 MST)
[AMMRL] Seeking Bruker 300WB Double Resonance Liquids Probe
David Cristea via groups.io
(Wed Oct 15 2025 - 00:35:09 MST)
[AMMRL] Seeking Open NMR Lab Manager Positions for a Highly Qualified Candidate
Shawn Wagner via groups.io
(Wed Oct 15 2025 - 07:10:15 MST)
[AMMRL] 800 Oxford pump magnet fridge vacuum problem
Wang, Tianzhi via groups.io
(Wed Oct 15 2025 - 11:09:29 MST)
Re: [AMMRL] 800 Oxford pump magnet fridge vacuum problem
Matthias Brandl via groups.io
(Wed Oct 15 2025 - 11:26:57 MST)
Re: [AMMRL] 800 Oxford pump magnet fridge vacuum problem
Wang, Tianzhi via groups.io
(Wed Oct 15 2025 - 13:13:45 MST)
Re: [AMMRL] 800 Oxford pump magnet fridge vacuum problem
falcocobra via groups.io
(Thu Oct 16 2025 - 08:34:51 MST)
[AMMRL] Facility policies for Variable Temperature Experiments?
Kenneth Sharp-Knott via groups.io
(Mon Oct 20 2025 - 07:46:36 MST)
Re: [AMMRL] Facility policies for Variable Temperature Experiments?
Vernon M Russell via groups.io
(Mon Oct 20 2025 - 08:46:52 MST)
Re: [AMMRL] Facility policies for Variable Temperature Experiments?
Fulton, Luke via groups.io
(Mon Oct 20 2025 - 09:00:19 MST)
Re: [AMMRL] Facility policies for Variable Temperature Experiments?
Charles Fry via groups.io
(Mon Oct 20 2025 - 09:20:26 MST)
Re: [AMMRL] Facility policies for Variable Temperature Experiments?
Karel Klika via groups.io
(Mon Oct 20 2025 - 14:39:48 MST)
Re: [AMMRL] Facility policies for Variable Temperature Experiments?
Michael Groves via groups.io
(Tue Oct 21 2025 - 07:00:48 MST)
Re: [AMMRL] Facility policies for Variable Temperature Experiments?
Karel Klika via groups.io
(Tue Oct 21 2025 - 07:45:11 MST)
Re: [AMMRL] Facility policies for Variable Temperature Experiments?
Akien, Geoffrey via groups.io
(Tue Oct 21 2025 - 08:58:14 MST)
Re: [AMMRL] Facility policies for Variable Temperature Experiments?
Sebastian Kemper via groups.io
(Mon Oct 20 2025 - 22:23:54 MST)
[AMMRL] Varian VnmrS digital controllers are off
Eugenio Alvarado via groups.io
(Tue Oct 21 2025 - 12:19:36 MST)
Re: [AMMRL] He Transfer Line pumpdown tool - Which one does this use?!
Kenneth Sharp-Knott via groups.io
(Wed Oct 22 2025 - 06:42:20 MST)
Re: [AMMRL] He Transfer Line pumpdown tool - Which one does this use?!
Jeffery Simpson via groups.io
(Wed Oct 22 2025 - 08:03:47 MST)
[AMMRL] AQS error
Delk, Michael Joseph via groups.io
(Wed Oct 22 2025 - 11:52:18 MST)
[AMMRL] Another iLab question
Anne Rachupka via groups.io
(Wed Oct 22 2025 - 13:41:05 MST)
Re: [AMMRL] Another iLab question
Fulton, Luke via groups.io
(Fri Oct 24 2025 - 08:56:14 MST)
[AMMRL] Varian Tutorial for MQMAS?
Casey Simons via groups.io
(Thu Oct 23 2025 - 13:30:40 MST)
[AMMRL] topshim solvcal gives "unknown exception in drucontr-TRX2 procedure"
Wendy Breyer via groups.io
(Fri Oct 24 2025 - 09:00:23 MST)
[AMMRL] Bruker 3.2mm MAS rotors
Fu Chen via groups.io
(Thu Oct 30 2025 - 09:35:24 MST)
Re: [AMMRL] Bruker 3.2mm MAS rotors
brcherry via groups.io
(Thu Oct 30 2025 - 09:43:06 MST)
Re: [AMMRL] Bruker 3.2mm MAS rotors
Casey Simons via groups.io
(Thu Oct 30 2025 - 09:55:39 MST)
Re: [AMMRL] Bruker 3.2mm MAS rotors
Spin-Doc
(Fri Oct 31 2025 - 06:59:44 MST)
Re: [AMMRL] Bruker 3.2mm MAS rotors
Fu Chen via groups.io
(Fri Oct 31 2025 - 11:43:09 MST)
[AMMRL] OpenVnmrJ Plotting to PDF
Shawn Wagner via groups.io
(Thu Oct 30 2025 - 14:17:50 MST)
Re: [AMMRL] OpenVnmrJ Plotting to PDF
Jessi Baughman via groups.io
(Fri Oct 31 2025 - 09:33:23 MST)
Last message date
:
Fri Oct 31 2025 - 12:35:29 MST
Archived on
: Sat Nov 01 2025 - 15:23:01 MST
120 messages
sort by
: [ thread ] [
author
] [
date
] [
subject
] [
attachment
]
Nearby
: [
Other mail archives
]
This archive was generated by
hypermail 2.4.0
: Sat Nov 01 2025 - 15:23:01 MST